1. Function description of automatic mode: 1) First select heating mode/cooling mode. 2) Set the temperature and hysteresis difference, if you need to delay start, set the time of delay start. 3) If you need to set high and low temperature alarms, set the high and low temperature alarm thresholds yourself
2. Description of heating mode: When the detected temperature (current temperature) less than equal set temperature - hysteresis temperature, the relay is turned on, and the heating equipment starts to work. When the detected temperature (current temperature) greater than equal the set temperature, the relay is disconnected and the heating device stops working
3. Description of cooling mode: When the detected temperature (current temperature) greater than equal set temperature + hysteresis temperature, the relay is turned on, and the refrigeration equipment starts to work. When the detected temperature (current temperature) less than equal the set temperature, the relay is disconnected and the refrigeration equipment stops working
4. Description of delayed start function: After a heating/cooling process is over, how long to delay (unit: seconds) to allow the next heating/cooling. Temperature correction function: If the system works for a long time, there may be deviations, which can be corrected by this function, the current temperature = measured temperature + calibration value
5. Emergency braking function (emergency stop function): After the emergency stop is turned on, the relay will be disconnected no matter what state it is in; after the emergency stop is turned off, the relay returns to the normal state. In the automatic mode, when the parameters are set, the product can be disconnected from the network and run offline, and the parameters will not be lost when the power is turned off.
High and low temperature alarm function
Buzzer on and off: After it is turned on, the buzzer will sound after the alarm, and when the button is pressed, the buzzer will stop sounding
High temperature alarm: After the high temperature alarm is turned on, the relay is disconnected when the current temperature is higher than the high temperature alarm temperature
Low temperature alarm: After the low temperature alarm is turned on, the relay is disconnected when the current temperature is lower than the low temperature alarm temperature
LAN data export function: The local area network will upload a piece of temperature data in 1 second. After clicking "Export", it will be automatically exported to EXCEL for analysis of the temperature data.
Temperature display: digital tube display
Supply voltage: DC 6-30V
USB power supply: support
Temperature control range: -40-110°C
Temperature control accuracy: 0.1℃
NTC temperature measurement range: -40-110℃
Whether to support 18B20: Yes (-40-110°℃)
Output type: relay switch, current within 10A
Alarm notification: support WeChat alarm notification
Cloud data record: 15 days cloud record, can be exported at any time
Timer switch function: support
color:Black
Material:plastic
Package Contents:
1 x Temperature controller module
1 x NTC sensing line
Only the above package content, other products are not included.
Note: Light shooting and different displays may cause the color of the item in the picture a little different from the real thing. The measurement allowed error is +/- 1-3cm.
About Us
We provide the good product with the best price,we support Wholesale/Drop Shipping Order
1. For Drop Shipping order, please remark"dropshipping order", we will prioritize it.
2. For Wholesale/Drop Shipping orders, if you have any ideas about the price or package,please contact us in advance,we will give you the best service to satisfy your demands.
About Shipments
1.We will send out the orders ASAP once your payment is completed normally.
2.Please write your complete delivery address with correct phone number and zip code, especially please confirm your full name.
About After-sale Service
We are reliable seller and we have our professional after-sale service for all of our customs. If there is any question about the order,please contact us in advance ,we will always here until you get a happy answer.
About Feedback
1. Please check the package and item when you get carefully to make sure there is no problem.
2. If you have any problem or are not entirely satisfied with your package,please don’t be hesitate to contact us first before leaving negative feedback. We will resolve the problem to satisfy you.
25404. If there is no problem, please leave us five star positive feedback.
Your affirmation is our greatest motivation ! ! !