Technical
Comprehensive error : 0.02% F.S
Sensitivity :1.0 0.1mv / v
Nonlinearity: 0.02% F.S
Hystis: 0.02% F.S
ance of :0.02% F.S
Creep: 0.02% F.S/10min
0:00 Output :2% F.S
Input Impedance :405 10
Output impedance :350 3
Insulation resistance :5000M (100V)
Excion voltage :5V ~ 12V
Temperature compensation range :10 ~ +40
Operating temperature range: -20 ~ +60
Temperature effect on zero 0.03% F.S/10
Temmp.effect 0.02% F.S/10
Safe oveoad 120%
Ultimate Oveoad 150%
Protection cl 65
Wiring
Bla Power + , white Power - Red Signal + green signal -
Use Special Note:
The r is a precision parts, severe ion , fall , collision ,
oveoad , overvoltage , etc. , are very likely to cause permanent damage to the r or
affect the accuracy and linearity , if you do not necessarily understand the parts ,
please buy carefully . After all, the resistance and capacitance transistors and components
compared to electronic components to be more fragile .
Resistance strain rMainly by the elastic body ,
the resistance strain cable and components ,
the internal circuit using Huygens bridge, when the elastic body is deformed under load ,
Resistance strain ( conversion ) film subjected to tensile or compressive strain deformation ,
its resistance will change ( increase or decrease ) , so that the bridge out of balance ,
a corresponding differential signal for subsequent measurement circuit and handling.