This website uses cookies
This website uses cookies. For further information on how we use cookies you can read our Privacy and Cookie notice
This website uses cookies. For further information on how we use cookies you can read our Privacy and Cookie notice
Shipped from abroad
Free return within 7 days for eligible items.Details
Yankkios
100%Seller Score
24 Followers
Shipping speed: Excellent
input voltage : DC12V/24V/36V/48V/60V/72V/96V
output voltage : AC220V
output power : 1500W/3000W/4000W/5000W/6000W/7500W/9000W
output frequency : 50Hz/60Hz 'adjustable'
size: 240mm * 100mm * 65mm
weight: about 0.82KG2.Transistors
12V 24V use HY1906
36V 48V use RIFB4710
60V use RIFB4710
72V use HY3215 HY3312
96V use HY1920
3.transformer
12V--use 6.5V to 220V transformer
24V--use 13V to 220V transformer 48V--use 26V to 220V transformer 36V--use 19V to 220V transformer 60V--use 32V to 220V transformer 72V--use 39V to 220V transformer 96V--use 52V to 220V transformer4.Features
1.enough power
2.pure sine wave
3.circuit is high efficient and stable
4.small no-load current
5.the battery has undervoltage / overload / overheat protection
6.Simple installation
7.work with all kinds of power frequency transformers
5.Protection
1. Battery low voltage protection:
When the battery voltage is lower than 10.5V per node, the inverter will turn off the inverter (there is no AC voltage output) and the inverter is in standby mode.
2. Battery over-voltage protection:
When the battery voltage is higher than 15V, the inverter will turn off the inverter and enter the standby mode.
3. The battery starts automatically:
When the battery is under-voltage protection, when the solar or wind energy charges the battery up to 13V per section, the inverter automatically starts to output the AC voltage to power the load. Battery overvoltage protection After the overvoltage protection and then restored to 15V per section, the inverter also starts automatically.
4. Temperature control fan and over-temperature protection:
Fan does not work during normal inverter operation, when the temperature is too high, the fan automatically runs, when the temperature drops, the fan automatically stops running. When the fan is damaged and the temperature is too high, the inverter will turn off the inverter and enter the standby mode.
When the temperature drops, it will automatically start the inverter and output AC power.
5 impact and short circuit protection:
The inverter has real-time hardware by wave current limit protection, and delay (400mS) short-circuit protection plus power frequency isolation transformer. Improves the impact resistance of the product The reliability of the product.
6.Driver board
The default setting of the driver board jumper is JP5, P2, JP7, JP8 short circuit, the corresponding function is 50Hz, 3S soft start, dead time 300ns,
Note: The same function jumper cannot be shorted at the same time!! If JP1 cannot be shorted with JP5 at the same time.LED to determine the type of fault
1. Normal: always bright
2. Overcurrent: blink twice, off two seconds, has been circulating
3. Overvoltage: blinking three times, off two seconds, has been cycling
4. Undervoltage: blinking four times, off two seconds, has been circulating
7.Note
1.Dear customer , if you have any technical probl , pls contact with customer service , we have specialist . thank you !Before shment, we have debugged, please rest aured to buy and use.
2.This link only has an inverter, other transformers need to be purchased separately.
8.Package
1pcs pure sine wave power frequency inverter board
About shping
This product has no ratings yet.
Subscribe to our newsletter
and be the first one to know about our amazing deals!