HomeAutomobileMotorcycle & PowersportsPartsControlsHand ControlsStabilizers & Dampeners50V 20A 1000W DC/DC Buck Converter CC CV Step-down Power Module LCD Adjustable Voltage
product_image_name-Generic-50V 20A 1000W DC/DC Buck Converter CC CV Step-down Power Module LCD Adjustable Voltage-1

Share this product

Shipped from abroad

50V 20A 1000W DC/DC Buck Converter CC CV Step-down Power Module LCD Adjustable Voltage

UGX 180,426
UGX 295,56439%

In stock

+ shipping from UGX 38,672 to Central Business District
0 out of 5
(No ratings available)
Variation available

Promotions

Delivery & Returns

Shipped from abroad 

Choose your location

Pickup Station

Delivery Fees UGX 38,672
Ready for pickup between 12 December & 17 December when you order within next 3hrs 10mins

Door Delivery

Delivery Fees UGX 45,572
Ready for delivery between 12 December & 17 December when you order within next 3hrs 10mins

Return Policy

Free return within 7 days for eligible items.Details

Seller Information

Auto parts, lighting accessories, and tools

60%Seller Score

Be the first to follow

Follow

Seller Performance

This seller does not have enough history for us to evaluate his performance yet

Product details


50V 20A 1000W DC/DC Buck Converter CC CV Step-down Power Module LCD Adjustable Voltage
  • I am an international seller
Our shop sells the most popular 3C consumer electronics products,such as mobile phone accessories,computer accessories,game peripherals,smart wearables,and follow the most popular fashion trends. If you like our products,please follow us,become our follower and fan.We will provide you with the most popular products to satisfy your fashion shopping experience.Personnalisé : OuiType actuel : Dc : CN Certification : CESupply Voltage : 0-50VOutput Current : 20A/12AOutput Voltage : 0-50VOutput Power : 1000W/600WType : Buck Converter


1. Item highlights: 1.1 LCD can display input/output voltage, output current/output power/output capacity/output time; 1.2. CNC adjustment, accurate and fast, can lower voltage, output voltage can be adjusted at will from , limit current 0-20.00a can be adjusted at will; 1.3. the output end is poured backward without burning; 1.4. The module can be set to open/close by default; 1.5. Multiple software protection mechanisms are available, and the protection threshold is adjustable.When the working of the module exceed the protection threshold, the output will be automatically closed. 1.6. Using synchronous rectification technology, the conversion efficiency is high: the efficiency is more than 90%. 1.7. Increase heat sink, install fan, strengthen heat dissipation.
2. Product  



model:WZ5020L
display:LCD


Input voltage range:6-55.00V
Input voltage resolution:0.01V


Output voltage range:0-50.00V
Output voltage resolution:0.01V


Output current range:0-20.00A
Output current resolution:0.01A


Output power range:0-1000W
Input voltage accuracy:±(1%+5)


Output voltage accuracy:±(0.3%+5)
Output current accuracy:±(0.5%+5)


Typical value of output ripple:150mV Peak value
Normal operating temperature range:-10℃~40℃


Capacity measurement range:0-999.9AH
Statistical error of capacity energy: ±2%


Statistical time range:0-100 hour
Depressurization mode:differential pressure >0.05%+1V


The weight of nude: 200g Including packing:242g
Product size: panel79X43X42mm main board:106x76x40mmSoft start: Yes Protection mechanism: Input undervoltage protection (5.8-50v adjustable, default 5.8v) Output overvoltage protection (0-51.00v adjustable, default 51V) Output over-current protection (0-20.10a adjustable, default 20.10a) Timeout protection (0 - 100h adjustable, off by default) Over capacity protection (0 – 999.9ah adjustable, off by default)
 3. Key descriptionNote: after the product triggers the protection mechanism, the output will automatically turn off, the LCD will display the protection e, and press any key to exit the protection interface 

4. Interface description

5. Method of use5.1. Switch display -- in the normal interface, press SW to switch the display below the display screen, and switch the display content between current A power W capacity Ah time h.Long press SW button to switch the uplink display on the display screen and switch the display content between input voltage IN output voltage OUT.5.2. Set output voltage -- press U/I button in the normal interface to enter the interface of setting voltage constant current.It can be seen that a certain digit of the output voltage value is flashing. Rotate the ener left and right to adjust the major and minor.Short press the rotary ener to choose which bit of output voltage to set.After setting, press U/I button 2 times to return to the normal interface.Or automatically return to the normal interface after stopping operation for 10s.5.3. Set constant current value (that is, the maximum current value allowed to output by the module) -- press U/I button in the normal interface to enter the setting voltage constant current interface.Then press U/I button and switch to setting constant current value. You can see a bit of the setting constant current value flashing. Rotate the rotary ener left and right to adjust the major and minor.Short press the rotary ener to choose which bit to set the constant current value.After setting, press U/I to exit the setting voltage constant current interface and return to the normal interface.Or automatically return to the normal interface after stopping operation for 10s.5.4. Set the default on/off state of module power-on -- long press U/I in the normal interface to enter the parameter setting interface.You can see that it shows "OPEN OFF" or "OPEN ON". "OPEN OFF" means the output is turned OFF by default when power is ON, and "OPEN ON" means the output is turned ON by default when power is ON.Long press rotate ener to switch two states.After setting, long press U/I to return to the normal interface.5.5. Setting of protection on state and threshold -- long press U/I to enter the parameter setting interface in the normal interface.Press SW until the protection you want appears.LUP -- undervoltage protection threshold;OUP -- overvoltage protection threshold;OCP -- overcurrent protection threshold;OAP -- ultra-capacity protection threshold;OHP timeout protection threshold.Short press rotate ener to select which bit you want to set the protection parameter.Long press the rotary ener to set the protection on or off (only timeout protection and supercapacity protection can be set to turn on/off, and other protection are turned on by default.).Rotate the ener left and right to make the bigger and smaller.After setting, long press U/I to return to the normal interface.5.6. Calibration voltage and current -- press U/I button to enter the parameter setting interface under normal interface. Press SW key for a short time until the interface with zero appears, with zero + out + a symbol. Press and hold the rotary ener to complete zero calibration. Short press SW button until a parameter interface with CAL appears.The calibration input voltage interface with the symbol CAL+IN+V;The calibration output voltage interface with the symbol CAL+OUT+V;The calibration output current interface with the symbol CAL+OUT+A.Rotate the ener left and right to adjust the size of .After the adjustment is completed, long press the rotary ener to confirm the adjustment is completed, and the parameter value is no longer flashing.Long press U/I to return to the normal interface. Note: in order to ensure the accuracy of calibration, calibration voltage -- above 12V can only be started;Calibration current - start calibration only when the current is above 1A.6 package
 
7. Cautions
7.1. The module input positive in + and negative in - must not be reversed, and the module input in - must not be short circuited with the output out -, otherwise the module may be burnt out.
7.2. Please ensure that the power moment of the power supply exceeds the required power of the output load!
7.3. This module is a step-down module, the input voltage should be higher than the output voltage, and a certain margin should be reserved. For full load output, the input voltage should be 55v.
7.4. High power use of this module, serious heating, high temperature, be careful of scald! Please pay attention to ventilation and heat dissipation when using high power for a long time!
7.5. The module has input undervoltage protection function. The default value is about 5.8v (can be set). When the value is lower than this value, the output will be automatically disconnected (note that the voltage at the module port is lower than the undervoltage protection threshold. When the input current is relatively large, do not ignore the partial voltage on the input wire).
 
 
WZ5012L 12A 600W
1. Item highlights:
1.1 LCD can display input/output voltage, output current/output power/output capacity/output time;
1.2. CNC adjustment, accurate and fast, can lower voltage, output voltage can be adjusted at will from 0-50.00v, limit current 0-12.00a can be adjusted at will;
1.3. the output end is poured backward without burning;
1.4. The module can be set to open/close by default;
1.5. Multiple software protection mechanisms are available, and the protection threshold is adjustable.When the working of the module exceed the protection threshold, the output will be automatically closed.
1.6. Using synchronous rectification technology, the conversion efficiency is high: the efficiency is more than 90%.
1.7. Increase heat sink, install fan, strengthen heat dissipation
 

 
2. Product

 



model:WZ5012L
display:LCD


Input voltage range:6-55.00V
Input voltage resolution:0.01V


Output voltage range:0-50.00V
Output voltage resolution:0.01V


Output current range:0-12.00A
Output current resolution:0.01A


Output power range:0-600.0W
Input voltage accuracy:±(1%+5)


Output voltage accuracy:±(0.3%+5)
Output current accuracy:±(0.5%+5)


Typical value of output ripple:150mV Peak value
Normal operating temperature range:-10℃~40℃


Capacity measurement range:0-999.9AH
Statistical error of capacity energy: ±2%


Statistical time range:0-100hour
Depressurization mode:differential pressure >0.05%+1V


The weight of nude: 199g Including packing:242g
Product size: panel79X43X42mm main board:106x76x40mm




Soft start: Yes
Protection mechanism:
Input undervoltage protection (5.8-50v adjustable, default 5.8v)
Output overvoltage protection (0-51.00v adjustable, default 51V)
Output over-current protection (0-12.10a adjustable, default 12.10a)
Timeout protection (0-100h adjustable, off by default)
Over capacity protection (0–999.9ah adjustable, off by default)

 
3. Key description



Note: after the product triggers the protection mechanism, the output will automatically turn off, the LCD will display the protection e, and press any key to exit the protection interface

4. Interface description

5. Method of use

5.1. Switch display -- in the normal interface, press SW to switch the display below the display screen, and switch the display content between current A power W capacity Ah time h.Long press SW button to switch the uplink display on the display screen and switch the display content between input voltage IN output voltage OUT.

5.2. Set output voltage -- press U/I button in the normal interface to enter the interface of setting voltage constant current.It can be seen that a certain digit of the output voltage value is flashing. Rotate the ener left and right to adjust the major and minor.Short press the rotary ener to choose which bit of output voltage to set.After setting, press U/I button 2 times to return to the normal interface.Or automatically return to the normal interface after stopping operation for 10s.

5.3. Set constant current value (that is, the maximum current value allowed to output by the module) -- press U/I button in the normal interface to enter the setting voltage constant current interface.Then press U/I button and switch to setting constant current value. You can see a bit of the setting constant current value flashing. Rotate the rotary ener left and right to adjust the major and minor.Short press the rotary ener to choose which bit to set the constant current value.After setting, press U/I to exit the setting voltage constant current interface and return to the normal interface.Or automatically return to the normal interface after stopping operation for 10s.

5.4. Set the default on/off state of module power-on -- long press U/I in the normal interface to enter the parameter setting interface.You can see that it shows "OPEN OFF" or "OPEN ON". "OPEN OFF" means the output is turned OFF by default when power is ON, and "OPEN ON" means the output is turned ON by default when power is ON.Long press rotate ener to switch two states.After setting, long press U/I to return to the normal interface.

5.5. Setting of protection on state and threshold -- long press U/I to enter the parameter setting interface in the normal interface.Press SW until the protection you want appears.LUP -- undervoltage protection threshold;OUP -- overvoltage protection threshold;OCP -- overcurrent protection threshold;OAP -- ultra-capacity protection threshold;OHP timeout protection threshold.Short press rotate ener to select which bit you want to set the protection parameter.Long press the rotary ener to set the protection on or off (only timeout protection and supercapacity protection can be set to turn on/off, and other protection are turned on by default.).Rotate the ener left and right to make the bigger and smaller.After setting, long press U/I to return to the normal interface.

5.6. Calibration voltage and current -- press U/I button to enter the parameter setting interface under normal interface. Press SW key for a short time until the interface with zero appears, with zero + out + a symbol. Press and hold the rotary ener to complete zero calibration. Short press SW button until a parameter interface with CAL appears.The calibration input voltage interface with the symbol CAL+IN+V;The calibration output voltage interface with the symbol CAL+OUT+V;The calibration output current interface with the symbol CAL+OUT+A.Rotate the ener left and right to adjust the size of .After the adjustment is completed, long press the rotary ener to confirm the adjustment is completed, and the parameter value is no longer flashing.Long press U/I to return to the normal interface. 
Note: in order to ensure the accuracy of calibration, calibration voltage -- above 12V can only be started;Calibration current - start calibration only when the current is above 1A

6. Cautions
6.1. The module input positive in + and negative in - must not be reversed, and the module input in - must not be short circuited with the output out -, otherwise the module may be burnt out.
6.2. Please ensure that the power moment of the power supply exceeds the required power of the output load!
6.3. This module is a step-down module, the input voltage should be higher than the output voltage, and a certain margin should be reserved. For full load output, the input voltage should be 55v.
6.4. High power use of this module, serious heating, high temperature, be careful of scald! Please pay attention to ventilation and heat dissipation when using high power for a long time!
6.5. The module has input undervoltage protection function. The default value is about 5.8v (can be set). When the value is lower than this value, the output will be automatically disconnected (note that the voltage at the module port is lower than the undervoltage protection threshold. When the input current is relatively large, do not ignore the partial voltage on the input wire). 
 
 
 


 
 
image

?width=804&height=804&hash=1608,
image

?width=800&height=806&hash=1606,
image


image

?width=722&height=323&hash=1045,
image

?width=725&height=512&hash=1237,
image

?width=2047&height=4016&hash=6063,
image


image

?width=800&height=806&hash=1606,
image

?width=800&height=806&hash=1606,
image

?width=729&height=427&hash=1156,

Specifications

Key Features

Personnalisé : OuiType actuel : Dc : CN Certification : CESupply Voltage : 0-50VOutput Current : 20A/12AOutput Voltage : 0-50VOutput Power : 1000W/600WType : Buck Converter


1. Item highlights: 1.1 LCD can display input/output voltage, output current/output power/output capacity/output time; 1.2. CNC adjustment, accurate and fast, can lower voltage, output voltage can be adjusted at will from , limit current 0-20.00a can be adjusted at will; 1.3. the output end is poured backward without burning; 1.4. The module can be set to open/close by default; 1.5. Multiple software protection mechanisms are available, and the protection threshold is adjustable.When the working of the module exceed the protection threshold, the output will be automatically closed. 1.6. Using synchronous rectification technology, the conversion efficiency is high: the efficiency is more than 90%. 1.7. Increase heat sink, install fan, strengthen heat dissipation.
2. Product  



model:WZ5020L
display:LCD


Input voltage range:6-55.00V
Input voltage resolution:0.01V


Output voltage range:0-50.00V
Output voltage resolution:0.01V


Output current range:0-20.00A
Output current resolution:0.01A


Output power range:0-1000W
Input voltage accuracy:±(1%+5)


Output voltage accuracy:±(0.3%+5)
Output current accuracy:±(0.5%+5)


Typical value of output ripple:150mV Peak value
Normal operating temperature range:-10℃~40℃


Capacity measurement range:0-999.9AH
Statistical error of capacity energy: ±2%


Statistical time range:0-100 hour
Depressurization mode:differential pressure >0.05%+1V


The weight of nude: 200g Including packing:242g
Product size: panel79X43X42mm main board:106x76x40mmSoft start: Yes Protection mechanism: Input undervoltage protection (5.8-50v adjustable, default 5.8v) Output overvoltage protection (0-51.00v adjustable, default 51V) Output over-current protection (0-20.10a adjustable, default 20.10a) Timeout protection (0 - 100h adjustable, off by default) Over capacity protection (0 – 999.9ah adjustable, off by default)
 3. Key descriptionNote: after the product triggers the protection mechanism, the output will automatically turn off, the LCD will display the protection e, and press any key to exit the protection interface 

4. Interface description

5. Method of use5.1. Switch display -- in the normal interface, press SW to switch the display below the display screen, and switch the display content between current A power W capacity Ah time h.Long press SW button to switch the uplink display on the display screen and switch the display content between input voltage IN output voltage OUT.5.2. Set output voltage -- press U/I button in the normal interface to enter the interface of setting voltage constant current.It can be seen that a certain digit of the output voltage value is flashing. Rotate the ener left and right to adjust the major and minor.Short press the rotary ener to choose which bit of output voltage to set.After setting, press U/I button 2 times to return to the normal interface.Or automatically return to the normal interface after stopping operation for 10s.5.3. Set constant current value (that is, the maximum current value allowed to output by the module) -- press U/I button in the normal interface to enter the setting voltage constant current interface.Then press U/I button and switch to setting constant current value. You can see a bit of the setting constant current value flashing. Rotate the rotary ener left and right to adjust the major and minor.Short press the rotary ener to choose which bit to set the constant current value.After setting, press U/I to exit the setting voltage constant current interface and return to the normal interface.Or automatically return to the normal interface after stopping operation for 10s.5.4. Set the default on/off state of module power-on -- long press U/I in the normal interface to enter the parameter setting interface.You can see that it shows "OPEN OFF" or "OPEN ON". "OPEN OFF" means the output is turned OFF by default when power is ON, and "OPEN ON" means the output is turned ON by default when power is ON.Long press rotate ener to switch two states.After setting, long press U/I to return to the normal interface.5.5. Setting of protection on state and threshold -- long press U/I to enter the parameter setting interface in the normal interface.Press SW until the protection you want appears.LUP -- undervoltage protection threshold;OUP -- overvoltage protection threshold;OCP -- overcurrent protection threshold;OAP -- ultra-capacity protection threshold;OHP timeout protection threshold.Short press rotate ener to select which bit you want to set the protection parameter.Long press the rotary ener to set the protection on or off (only timeout protection and supercapacity protection can be set to turn on/off, and other protection are turned on by default.).Rotate the ener left and right to make the bigger and smaller.After setting, long press U/I to return to the normal interface.5.6. Calibration voltage and current -- press U/I button to enter the parameter setting interface under normal interface. Press SW key for a short time until the interface with zero appears, with zero + out + a symbol. Press and hold the rotary ener to complete zero calibration. Short press SW button until a parameter interface with CAL appears.The calibration input voltage interface with the symbol CAL+IN+V;The calibration output voltage interface with the symbol CAL+OUT+V;The calibration output current interface with the symbol CAL+OUT+A.Rotate the ener left and right to adjust the size of .After the adjustment is completed, long press the rotary ener to confirm the adjustment is completed, and the parameter value is no longer flashing.Long press U/I to return to the normal interface. Note: in order to ensure the accuracy of calibration, calibration voltage -- above 12V can only be started;Calibration current - start calibration only when the current is above 1A.6 package
 
7. Cautions
7.1. The module input positive in + and negative in - must not be reversed, and the module input in - must not be short circuited with the output out -, otherwise the module may be burnt out.
7.2. Please ensure that the power moment of the power supply exceeds the required power of the output load!
7.3. This module is a step-down module, the input voltage should be higher than the output voltage, and a certain margin should be reserved. For full load output, the input voltage should be 55v.
7.4. High power use of this module, serious heating, high temperature, be careful of scald! Please pay attention to ventilation and heat dissipation when using high power for a long time!
7.5. The module has input undervoltage protection function. The default value is about 5.8v (can be set). When the value is lower than this value, the output will be automatically disconnected (note that the voltage at the module port is lower than the undervoltage protection threshold. When the input current is relatively large, do not ignore the partial voltage on the input wire).
 
 
WZ5012L 12A 600W
1. Item highlights:
1.1 LCD can display input/output voltage, output current/output power/output capacity/output time;
1.2. CNC adjustment, accurate and fast, can lower voltage, output voltage can be adjusted at will from 0-50.00v, limit current 0-12.00a can be adjusted at will;
1.3. the output end is poured backward without burning;
1.4. The module can be set to open/close by default;
1.5. Multiple software protection mechanisms are available, and the protection threshold is adjustable.When the working of the module exceed the protection threshold, the output will be automatically closed.
1.6. Using synchronous rectification technology, the conversion efficiency is high: the efficiency is more than 90%.
1.7. Increase heat sink, install fan, strengthen heat dissipation
 

 
2. Product

 



model:WZ5012L
display:LCD


Input voltage range:6-55.00V
Input voltage resolution:0.01V


Output voltage range:0-50.00V
Output voltage resolution:0.01V


Output current range:0-12.00A
Output current resolution:0.01A


Output power range:0-600.0W
Input voltage accuracy:±(1%+5)


Output voltage accuracy:±(0.3%+5)
Output current accuracy:±(0.5%+5)


Typical value of output ripple:150mV Peak value
Normal operating temperature range:-10℃~40℃


Capacity measurement range:0-999.9AH
Statistical error of capacity energy: ±2%


Statistical time range:0-100hour
Depressurization mode:differential pressure >0.05%+1V


The weight of nude: 199g Including packing:242g
Product size: panel79X43X42mm main board:106x76x40mm




Soft start: Yes
Protection mechanism:
Input undervoltage protection (5.8-50v adjustable, default 5.8v)
Output overvoltage protection (0-51.00v adjustable, default 51V)
Output over-current protection (0-12.10a adjustable, default 12.10a)
Timeout protection (0-100h adjustable, off by default)
Over capacity protection (0–999.9ah adjustable, off by default)

 
3. Key description



Note: after the product triggers the protection mechanism, the output will automatically turn off, the LCD will display the protection e, and press any key to exit the protection interface

4. Interface description

5. Method of use

5.1. Switch display -- in the normal interface, press SW to switch the display below the display screen, and switch the display content between current A power W capacity Ah time h.Long press SW button to switch the uplink display on the display screen and switch the display content between input voltage IN output voltage OUT.

5.2. Set output voltage -- press U/I button in the normal interface to enter the interface of setting voltage constant current.It can be seen that a certain digit of the output voltage value is flashing. Rotate the ener left and right to adjust the major and minor.Short press the rotary ener to choose which bit of output voltage to set.After setting, press U/I button 2 times to return to the normal interface.Or automatically return to the normal interface after stopping operation for 10s.

5.3. Set constant current value (that is, the maximum current value allowed to output by the module) -- press U/I button in the normal interface to enter the setting voltage constant current interface.Then press U/I button and switch to setting constant current value. You can see a bit of the setting constant current value flashing. Rotate the rotary ener left and right to adjust the major and minor.Short press the rotary ener to choose which bit to set the constant current value.After setting, press U/I to exit the setting voltage constant current interface and return to the normal interface.Or automatically return to the normal interface after stopping operation for 10s.

5.4. Set the default on/off state of module power-on -- long press U/I in the normal interface to enter the parameter setting interface.You can see that it shows "OPEN OFF" or "OPEN ON". "OPEN OFF" means the output is turned OFF by default when power is ON, and "OPEN ON" means the output is turned ON by default when power is ON.Long press rotate ener to switch two states.After setting, long press U/I to return to the normal interface.

5.5. Setting of protection on state and threshold -- long press U/I to enter the parameter setting interface in the normal interface.Press SW until the protection you want appears.LUP -- undervoltage protection threshold;OUP -- overvoltage protection threshold;OCP -- overcurrent protection threshold;OAP -- ultra-capacity protection threshold;OHP timeout protection threshold.Short press rotate ener to select which bit you want to set the protection parameter.Long press the rotary ener to set the protection on or off (only timeout protection and supercapacity protection can be set to turn on/off, and other protection are turned on by default.).Rotate the ener left and right to make the bigger and smaller.After setting, long press U/I to return to the normal interface.

5.6. Calibration voltage and current -- press U/I button to enter the parameter setting interface under normal interface. Press SW key for a short time until the interface with zero appears, with zero + out + a symbol. Press and hold the rotary ener to complete zero calibration. Short press SW button until a parameter interface with CAL appears.The calibration input voltage interface with the symbol CAL+IN+V;The calibration output voltage interface with the symbol CAL+OUT+V;The calibration output current interface with the symbol CAL+OUT+A.Rotate the ener left and right to adjust the size of .After the adjustment is completed, long press the rotary ener to confirm the adjustment is completed, and the parameter value is no longer flashing.Long press U/I to return to the normal interface. 
Note: in order to ensure the accuracy of calibration, calibration voltage -- above 12V can only be started;Calibration current - start calibration only when the current is above 1A

6. Cautions
6.1. The module input positive in + and negative in - must not be reversed, and the module input in - must not be short circuited with the output out -, otherwise the module may be burnt out.
6.2. Please ensure that the power moment of the power supply exceeds the required power of the output load!
6.3. This module is a step-down module, the input voltage should be higher than the output voltage, and a certain margin should be reserved. For full load output, the input voltage should be 55v.
6.4. High power use of this module, serious heating, high temperature, be careful of scald! Please pay attention to ventilation and heat dissipation when using high power for a long time!
6.5. The module has input undervoltage protection function. The default value is about 5.8v (can be set). When the value is lower than this value, the output will be automatically disconnected (note that the voltage at the module port is lower than the undervoltage protection threshold. When the input current is relatively large, do not ignore the partial voltage on the input wire). 
 
 
 


 
 

What’s in the box

1x packages

Specifications

  • SKU: GE779VP4O6F75NAFAMZ
  • Model: SM-WDQ-4-15-439
  • Production Country: China
  • Size (L x W x H cm): 20x10x20
  • Weight (kg): 0.3
  • Color: 600W 12A
  • Main Material: other

Customer Feedback

This product has no ratings yet.

50V 20A 1000W DC/DC Buck Converter CC CV Step-down Power Module LCD Adjustable Voltage

50V 20A 1000W DC/DC Buck Converter CC CV Step-down Power Module LCD Adjustable Voltage

UGX 180,426
UGX 295,56439%
Questions about this product?

Recently Viewed

See All