Description:
Supports cumulative data reset and forced zero reset with no load
Supports voltage display fine tuning and current display fine tuning
Columnar temperature waterproof probe, temperature measurement range -40~120 ℃
High definition IPS LCD color screen with a resolution of 135 x 240
Can simultaneously measure voltage, current, power, percentage, electricity, temperature, cumulative capacity, energy, operating time
10A technical s:
Instrument working voltage: XH-3P red blawire DC4~30V do not overvoltage power supply
Introduction to Wire Definition:
XH-2.54-3P red blayellow wire total length of thin wire: 155mm
Thin red wire: the positive pole of the working power supply cannot be connected to a power supply above 30V
Thin blawire: The negative pole of the working power supply is grounded together with the thiblawire, and there is no need to connect it when sharing the power supply
Thin yellow wire: voltage test wire, connected to the positive pole of the test circuit power supply
VH-3.96-2P thired blawire total length of thiwire: 165mm current test wire, parallel s of thiwire, cannot be directly connected to the two poles of the power supply, and may cause short circuit
Thired wire: current test positive pole, connected in series at the baend of the negative pole of the load, and connected first and then disconnected when connecting the wire
Thiblawire: current test negative pole, connect to the negative pole of the power supply, and connect the broken wire first and then disconnect it
Connection diverter: On board low-temperature drift alloy resistance s, can be directly connected according to the wiring diagram
Voltage measurement range: DC0~100V Error ± 1.00V 0.1V Jump
Current measurement range: 0.00A~10.00A Error ± 0.1A 0.03A Jump
Power measurement range: 00.00~1000W
Capacity measurement range: 0~9999999mAh
Energy metering range: 0~9999999mWh
Temperature r: cylindrical waterproof probe NTC 10K 3950 1% r with a total length of approximately 1 meter
Temperature measurement range: -40~120 ℃ external temperature measured by NTC r
Time measurement range: 0~999:59:59 hour: minute: second
Working energy consumption: 20mA measured at DC12V
Support: Accumulated data reset, no load forced reset, voltage display, fine adjustment, current display, fine adjustment
Percentage battery display: Based on voltage reference, the percentage battery full and low battery voltages need to be manually set
Product size: 47.59 × twenty-eight point six seven × 25.33mm
Installation hole: 45 × 26mm
50A technical s:
Instrument working voltage: XH-3P red blawire DC4~30V do not overvoltage power supply
Introduction to Wire Definition:
XH-2.54-3P red blayellow wire total length of thin wire: 155mm
Thin red wire: the positive pole of the working power supply cannot be connected to a power supply above 30V
Thin blawire: The negative pole of the working power supply is grounded together with the thiblawire, and there is no need to connect it when sharing the power supply
Thin yellow wire: voltage test wire, connected to the positive pole of the test circuit power supply
VH-3.96-2P thired blawire total length of thiwire: 165mm current test wire, thiwire cannot be directly connected to the two poles of the power supply, which will cause a short circuit
Thired line: current test positive pole, parallel s connected to the rear end of the negative pole of the load
Thiblawire: current test negative pole, parallel s connected to power negative pole
Connecting the splitter: A parallel 50A 75mV splitter is required to use the splitter needs to be provided by ones
Voltage measurement range: DC0~100V Error ± 1.00V 0.1V Jump
Current measurement range: 0.00A~50.00A Error ± 0.5A 0.03A Jump
Power measurement range: 00.00~5000W
Capacity measurement range: 0~9999999mAh
Energy metering range: 0~9999999mWh
Temperature r: cylindrical waterproof probe NTC 10K 3950 1% r with a total length of approximately 1 meter
Temperature measurement range: -40~120 ℃ external temperature measured by NTC r
Time measurement range: 0~999:59:59 hour: minute: second
Working energy consumption: 20mA measured at DC12V
Support: Accumulated data reset, no load forced reset, voltage display, fine adjustment, current display, fine adjustment
Percentage battery display: Based on voltage reference, the percentage battery full and low battery voltages need to be manually set
Product size: 47.59 × twenty-eight point six seven × 25.33mm
Installation hole: 45 × 26mm
100A technical s:
Instrument working voltage: XH-3P red blawire DC4~30V do not overvoltage power supply
Introduction to Wire Definition:
XH-2.54-3P red blayellow wire total length of thin wire: 155mm
Thin red wire: the positive pole of the working power supply cannot be connected to a power supply above 30V
Thin blawire: The negative pole of the working power supply is grounded together with the thiblawire, and there is no need to connect it when sharing the power supply
Thin yellow wire: voltage test wire, connected to the positive pole of the test circuit power supply
VH-3.96-2P thired blawire total length of thiwire: 165mm current test wire
The parallel s with thiwires cannot be directly connected to the two poles of the power supply, which may cause a short circuit
Thired line: current test positive pole, parallel s connected to the negative end of the load in series.
Thiblawire: current test negative pole, parallel s connected to power negative pole.
Connecting the splitter: A parallel 100A 75mV splitter is required to use the splitter needs to be provided by ones
Voltage measurement range: DC0~100V Error ± 1.00V 0.1V Jump
Current measurement range: 0.00A~100.00A Error ± 1A 0.03A Jump
Power measurement range: 00.00~9999W
Capacity measurement range: 0~9999999mAh
Energy metering range: 0~9999999mWh
Temperature r: cylindrical waterproof probe NTC 10K 3950 1% r with a total length of approximately 1 meter
Temperature measurement range: -40~120 ℃ external temperature measured by NTC r
Time measurement range: 0~999:59:59 hour: minute: second
Working energy consumption: 20mA measured at DC12V
Support: Accumulated data reset, no load forced reset, voltage display, fine adjustment, current display, fine adjustment
Percentage battery display: Based on voltage reference, the percentage battery full and low battery voltages need to be manually set
Product size: 47.59 × twenty-eight point six seven × 25.33mm
Installation hole: 45 × 26mm
Electronic manual:
10A:https://www.banber.com/gather/64c7518903dc0b3d70f25790
50A:https://www.banber.com/gather/64c751a803dc0b3d70f258f0
100A: https://www.banber.com/gather/64c7519c03dc0b3d70f25840
Package include:
1pc x 8 In 1 Dial DC 4-30V 10/50/100A Power Energy Wattmeter Capacity LCD Display
1pc x Cylindrical waterproof probe sensing line
1pc x XH-2.54-3P Red blayellow wire
1pc x VH-3.96-2P thired blawire