ANENG Q1 True-RMS Digital Multimeter Button 9999 Counts With Analog Bar Graph AC/DC Voltage Current Ohm Auto/Manual
Please Note you have to reading the operate manual first before use,otherwise you will burn the device with wrong operat.
Specifications:
Brand Name
ANENG
Model Number
Q1
Display (LCD)
9999 Counts
Ranging
Auto/Manual
Material
ABS+TPE
Update Rate
3 Times/Second
Ture RMS
YES
Data Hold
YES
Relative Value Measurement
YES
Low Battery Indication
YES
Balight
YES
Auto Power Off
YES
Operating
Tenperature
0~40°C
Hunidity
75%
Storage
Tenperature
-20~60°C
Hunidity
80%
Funtion
Range
Accuracy
DC voltage (V)
999.9mV/9.999V/99.99V/999.9V
±(0.5%+3)
DC voltage (mV)
9.999mV /99.99mV
±(0.5%+3)
AC voltage (V)
999.9mV/9.999V/99.99V/750.0V
±(1.0%+3)
AC voltage (mV)
9.999mV /99.99mV
±(1.0%+3)
DC Current (mA&A)
999.9mA/9.999A
±(1.0%+3)
DC Current (A)
9999A
±(0.8%+3)
AC Current (mA&A)
999.9mA/9.999A
±(1.0%+3)
AC Current(A)
9999A
±(1.0%+3)
Resistance
99.99
±(1.0%+3)
Resistance
999.9 /9.999k /99.99k /999.9k /
±(0.5%+3)
Resistance
9.999M
±(1.5%+3)
Resistance
99.99M
±(3.0%+5)
9.999nF
±(5.0%+20)
99.99nF /999.9nF /9.999F /99.99F /999.9F
±(2.0%+5)
9.999mF
±(5.0%+5)
Frequency
99.99Hz /999.9Hz /9.999kHz /99.99kHz /999.9kHz /2.000MHz
±(0.1%+2)
Duty cycle
1%~99%
±(0.1%+2)
Diode :YES
Continuity :YES
NCV :YES
Temperature
(-20~1000)° /(-4~1832)°
±(2.5%+5)
Power
2 * 1.5V AA batteries
(Not Included)
Sample Rate
3 times per second
Pa content:
1 x Multimeter
1 x Test lead+temperature r
1 x User Manual
1 x Storage bag
1 x 16pc Test probe
Note:
1. Do NOT exceed the maximum value indicated in the Specification;
2. Do NOT input voltage at the Current Mode, the Resistance Mode, the Diode Mode, the Continuity Mode, or the Temperature Mode;
3. Do NOT use the product when the batteries or the battery cover is not placed properly;
4. Turn off the product and remove the test leads from the test points before changing batteries or .
5. Do not input voltage exceeds 36V DC or 25V AC when you are at the setting of measuring current.
About shping
This product has no ratings yet.
Subscribe to our newsletter
and be the first one to know about our amazing deals!