Quality Score: Excellent
doubleveinpunchingArgon arc welding weldin welding control instead of imitationimplementA modified spot welding for argon arc welding , Imitation and the development of cold welding specification , Multi welding form , Double pulseSimple and simpletimeController , Direct loading on the argon arc welding hine , Do not affect the function of the welding hine , Simple wiring , The operation is very convenient . mainFor thin platesweldmeet . The use of little input will allow your ordinary argon arc welder to have a profeional cold welder. , Precision workpiece welding can be realized easily .
The main features of the controller :
1: Output adoptionExclusive designTheDouble relay rotation output , Greatly increased
Add the service life of the controller
2: On-board isolation power supply , Enhanced inputoutputPower supply anti-jammingmeter
3: Design of industrial MCU , Pulse time control is accurate to milliseconds
level , Double pulse output , Any set of time is 0, onCan be regarded as
Monopulse use
4: Multi specification , Most can be set 15 Group parameters
5:5 Window display data , Display the specification number, respectively ,I, II Pulse width and pulse width I, II
Pulse interval
6: Control mode with single point welding , Continuous welding , welding
7: Parameters are adjusted to key and encoder input methods , More accurate and convenient
8: pulse width 1-999, Pulse interval 1-999, Company MS
9: Multi indicator lamp , Let you know the working state of the control at a glance , Color has special design , Even if it's far away from it , You can also distinguish the working state of the controller
Physical wiring diagram, intuitively clear
Baby detail
Instructions
This controller has 3 Control mode
Single point welding : Only to weld each time
Continuous welding : As long as the trigger switch is closed , On the output of continuous pulse
welding : Using the argon arc welding function welding
exercisedo :
Click [ set upThe / Sign out ] Key , howeverPa through [I] and [To] Pre
key , Selectedcontrol model , herethroughKnobCanSelect operation mode ,
After the choice is finished , Pre it again [ set upThe / Sign out ] Key , Can be savedModel
Type A .
2: Standard selection
This controller can be saved 15 Specification for str welding
The standard number digital tube displays the current usage specification , Pulse width at the same time , pulse
Interval displays the parameter values of the current specification
exercisedo :
Click [ set upThe / Sign out ] Key , howeverPa through [I] and [To] Pre
key , SelectedgaugeFan. , herethroughOver the knobSureChoicegaugeFan. , Choice
After the end , Pre it again [ set upThe / Sign out ] Key , Can be savedgaugeFan.
The .
3: pulse widthAnd interval
The pulse width refers to the time of the output pulse. , The interval of the pulse is the interval of the pulse
time .
exercisedo :
Click [ set upThe / Sign out ] Key , howeverPa through [I] and [To] Prekey , SelectedThe width and interval to be set , thistimethroughA knob can be donetransferNode parameter , transfersectionAfter the end , Pre it again [ set upThe / Sign out ] Key , Can be savedginsengnumber .
NY-YHD01 modified argon arc spot welding control board is a response to the modified argon arc welding, cold welding and the development of generic specification, welding time controller simple form, directly installed in the argon arc welding hine, welding hine does not affect the function, wiring is simple, the operation is very convenient. The use of a few inputs will allow you to argon arc welding hine common profeional cold welding welding effect, can easily achieve the precision welding. The main features of the controller are: 1: output with exclusive design of double relay rotation, greatly increase Add the service life of the controller 2: enhanced input, output, power supply anti-jamming design 3: with the design of industrial MCU, pulse time control is accurate to millisecond 4: multi specification, up to 20 sets of parameters The 5:3 window displays the data, showing the standard number, the pulse width and the pulse, respectively interval 6: the control mode is single point welding, continuous welding, welding 7: the parameters are adjusted to key and encoder input methods, more accurate and convenient 8: pulse width is 1-999, pulse interval is 1-999, unit MS 9: multi indicator light, allowing you to control the working state at a glance, color A special design, even if it's far away, you can tell the controller. working condition 10: the power line and the foot switch line use no screw fast connection terminal, more convenient and reliable Physical wiring diagram, intuitively clear
Instructions: 1: change control mode There are 3 control modes for this controller Single point welding: one trigger only produces one pulse Continuous welding: as long as the trigger switch is closed, the continuous pulse is output welding: using the argon arc welding function welding Operation: Click the on, the code number, the pulse width, the pulse interval The light will be bright, and the operation mode can be selected by the knob. After that, click the on and save the mode. 2: standard selection This controller can save 20 welding specifications The code number digital tube displays the current specification, pulse width, pulse The blanking interval displays the parameter values of the current specification Operation: When other specification numbers are selected, click the on and specification The number indicator light, the rotary knob can choose the standard number. Pre it again The code number can be saved by the on 3: pulse width and interval The pulse width refers to the time of the output pulse, and the pulse width refers to the continuous output. The interval between two pulses. Operation: Click on the width / interval on, the pulse width indicator lights up, the rotating swirl The on can adjust the pulse width parameters, and then pre the width / interval. Key, the pulse interval indicates the light, and the rotating knob can adjust the pulse interval Parameters. Pre the width / interval on, and the pulse width can be saved. And pulse width parameters.