This website uses cookies
This website uses cookies. For further information on how we use cookies you can read our Privacy and Cookie notice
This website uses cookies. For further information on how we use cookies you can read our Privacy and Cookie notice
Shipped from abroad
Free return within 7 days for eligible items.Details
Sweet Memories
74%Seller Score
18 Followers
Shipping speed: Good
Quality Score: Excellent
Customer Rating: Poor
Big Retailers We have big retailers in Ruia, if it is not inconvenient for you to order the products from our China warehouse, you can contact us to get the way to buy in local store. Technical Support If you have any questions about our products, welcome to contact us in these ways,for now we support Tencent QQ group, WeChat group and WhatsApp, here is the contact information. QQ Group:550112838 WeChat:15868147353 WhatsApp:+8615868147353
LD35/LD25 is new USB Intelligent electronic load, if you want to learn more, please clear here : https://www.aliexpre.com/store/product/RD-LD25-Electronic-Load--USB-Interface-Discharge-battery-test-LED-display-fan-adjustable-current-voltage/923042_32882318330.html
HD35 is USB trigger Intelligent electronic load, if you want to learn more, please clear here: https://www.aliexpre.com/item/RD-HD25-HD35-Trigger-QC2-0-QC3-0-Electronic-USB-Load--Discharge-battery-test-adjustable/32917594486.html
AT34 is the origin model of AT35, 4-digit display,if you want to learn more, please clear here: https://www.aliexpre.com/store/product/RD-AT34-USB-3-0-color-LCD---voltage-current-meter-multimeter-battery-charge-power/923042_32897200670.html?spm=2114.12010612.8148356.13.64ae373cZuo7JE
Instruction for USB with Full Colour Display
-Model :AT35
Thank you for purchasing this Full Colour USB from Hangzhou Ruideng Technology Co., Ltd. Prior to using this product we recommend that you briefly familiarize yourself with this instruction in order to ensure the correct operation and use of the device. We also advise that you keep this instruction in a safe place for future reference as may be needed sometime.
Technical Parameter:
Product Model
AT34
AT35
Voltage measurement range
3.70-30.00V
3.700-30.000V
Voltage measurement resolution
0.01V
0.001V
Voltage measurement accuracy
±(0.8%+4digits )
±(0.1%+2digits)
Current measurement range
0-4.000A
0-4.0000A
Current measurement resolution
0.001A
0.0001A
Current measurement resolution
±(1%+4digits )
±(0.2%+4 digits)
Product weight(paage included)
28g
27g
Data refresh rate
2Hz
0.5Hz
Display screen
0.96 Inch color S display
Capacity accumulation range
0-99999mAh
Energy accumulation range
0-99999mWh 999.99W
Power measurement range
0-120W
Load impedance range
1Ω-9999.9Ω
Temperature range
0℃~80℃/32℉~176℉
Temperature measurement error
±3℃/±6℉
Working temperature range
0~45℃/32℉~113℉
Dimension
64mmx22mmx12mm
Qui charge recognition mode
QC2.0、QC3.0、APPLE 2.4A/2.1A/ 1A/0.5A、Android DCP、SAMSUNG
Note:
1, User manual: http://www.ruidengkeji.com/inst/AT35.pdf (Chinese Server)
https://drive.google.com/open?id=1qoLO4A9RjR7XTNXrvXejGSNn_Uyp (Google Cloud Disk)
2. Descrtion video : https://youtu.be/gSXDez7hW0k
Function Interface:
Measurement Main Interface Qui Charge Recognition Interface
Button Instruction:
The button is located on ba of the . There are 2 ways of operation, long pre and short pre. Short pre is to realize switch between Main Interface and Qui Charge Recognition Interface. Long pre is to realize switch of system setting.
Introduction of Icon Function
1. Pre and hold the button to choose this icon to turn on/off the screen.
2. Pre and hold the button to choose this icon to switch the temperature unit(℃/℉).
3. Pre and hold the button to choose this icon to switch data group.
4. Pre and hold the button to choose this icon to clear data in current data group.
5. Pre and hold the button to choose this icon to rotate the screen.
Operation Instruction:
hold the button and power on the device without load, the current base can be cleared. If you do this with load, the current will always be 0. After the normal power-on, the welcome interface will be displayed first, and then the measurement main interface will be displayed.
Interface 1: Measurement Main Interface:
6:Voltage Measurement Value
7:Current Measurement Value
8:Accumulated Capacity
9:Accumulated Energy
10:Temperature Measurement Value
11:Number of the Data Group in use
12:Load Equivalent Impedance
13:Power Measurement Value
Pre the button on the ba to switch to Qui Charge Recognition Interface
Interface 2: Qui Charge Recognition Interface:
14:D+: data positive signal voltage
15:D-: data negative signal voltage
16:Current qui charge mode display
The product will automatically identify a device with a supported fast charging mode. At this time the device supports the QC2.0、QC3.0、APPLE2.4A/2.1A/1A/0.5A、Android DCP、SAMSUNG. ( Note : D+/D- voltage and qui charge protocol recognition function is for reference only, because mobile phone is updated quily, it can't be absolutely accurate)
Parameter Setting:At any interface of 2 interfaces, Pre and hold the button to realize data set. Long pre the button for more than 0.5s, the corresponding icon will be selected and displayed (the baground of icon becomes blue), then step through the options of screen off, temperature display units, data group switch, data group clear zero and screen rotation. Stop on the function you wish to set, and then loosen the button.
Pre and hold the button, when the corresponding icon is selected and displayed, loosen the button, screen will be turned off, and then pre the button or power on again, the display will light again.
Pre and hold the button, when the corresponding icon is selected and displayed, loosen the button, the temperature unit will be switched. Default temperature unit: degrees Celsius.
Pre and hold the button, when the corresponding icon is selected and displayed, loosen the button and data group will be switched. This can provide 2 groups to store and che, data group 0 and data group 1. When the data set is group 0, the current capacity and energy will be stored after power off. When power on next time, the stored mAh and mWh is blinking displayed. When the new mAh is accumulated up to 1mAh, the stored mAh and mWh will be covered, and the values will start over. When data set is group 1, the current capacity will be stored after power off. And the stored capacity will be accumulated after power on.
Pre and hold the button, when the corresponding icon is selected and displayed, loosen the button, the data of the current data group will be cleared.
Pre and hold the button, when the corresponding icon is selected and displayed, loosen the button, the screen will be rotated 180 degree, and stored automatically, which is convenient for later using.
About shping
This product has no ratings yet.
Subscribe to our newsletter
and be the first one to know about our amazing deals!