HomeElectronicsAccessories & SuppliesAudio & Video AccessoriesTV Accessories & PartsBattery Voltage Monitor Module DC 12V Low Voltage Cut Off Charge Discharge Protection Board for 0-99V Lead Acid Li Battery
product_image_name-Generic-Battery Voltage Monitor Module DC 12V Low Voltage Cut Off Charge Discharge Protection Board for 0-99V Lead Acid Li Battery-1product_image_name-Generic-Battery Voltage Monitor Module DC 12V Low Voltage Cut Off Charge Discharge Protection Board for 0-99V Lead Acid Li Battery-2product_image_name-Generic-Battery Voltage Monitor Module DC 12V Low Voltage Cut Off Charge Discharge Protection Board for 0-99V Lead Acid Li Battery-3product_image_name-Generic-Battery Voltage Monitor Module DC 12V Low Voltage Cut Off Charge Discharge Protection Board for 0-99V Lead Acid Li Battery-4product_image_name-Generic-Battery Voltage Monitor Module DC 12V Low Voltage Cut Off Charge Discharge Protection Board for 0-99V Lead Acid Li Battery-5

Share this product

Shipped from abroad

Battery Voltage Monitor Module DC 12V Low Voltage Cut Off Charge Discharge Protection Board for 0-99V Lead Acid Li Battery

UGX 117,140
UGX 163,91829%

In stock

+ shipping from UGX 21,814 to Central Business District
0 out of 5
(No ratings available)
Variation available

Promotions

Delivery & Returns

Shipped from abroad 

Choose your location

Pickup Station

Delivery Fees UGX 21,814
Ready for pickup between 16 December & 20 December when you order within next 11hrs 15mins

Door Delivery

Delivery Fees UGX 22,914
Ready for delivery between 16 December & 20 December when you order within next 11hrs 15mins

Return Policy

Free return within 7 days for eligible items.Details

Seller Information

Niduo

60%Seller Score

Be the first to follow

Follow

Seller Performance

This seller does not have enough history for us to evaluate his performance yet

Product details


Battery Voltage Monitor Module DC 12V Low Voltage Cut Off Charge Discharge Protection Board for 0-99V Lead Acid Li Battery
  • I am an international seller
Our shop sells the most popular 3C consumer electronics products,such as mobile phone accessories,computer accessories,game peripherals,smart wearables,and follow the most popular fashion trends. If you like our products,please follow us,become our follower and fan.We will provide you with the most popular products to satisfy your fashion shopping experience.Condition : NewType : Voltage RegulatorBrand Name : ISOrigin : Mainland ChinaFeature : Low Voltage DisconnectFeature1 : Low Voltage CutoffFeature2 : Charging Discharging Protection BoardSuitalbe for : 0-99V Lead Acid Lithium Battery Solar Panel Camper【INDEPENDENT WORKING VOLTAGE】In order to avoid consuming the voltage of the battery being measured, the device can be separately connected to another power supply as its working voltage【CHARGE AND DISCHARGE PROTECTION】You can freely set the charging or discharging mode and set . For example, when the battery voltage reaches the set voltage, the module will automatically disconnect to avoid battery over-discharging and prolong battery life【INTERZONE VOLTAGE PROTECTION】This means that you can set the number of values between which the voltage will disconnect or connect the relay【FIXED VOLTAGE MONITORING】When the measured voltage is higher than the set voltage value, the relay is connected, otherwise it will be disconnected. Alternatively, you can set it to always stay connected until you manually power off, and the relay outputs a pulse signal when the measured voltage is equal to the set voltage (up and down 0.1V)【PARAMETER】Working voltage: DC 12V; ?Measuring Range: DC 0-99.9V; ?Board size: 43.7*56mm; ?Load current:15A(Max); ?Load voltage:DC0-30V or AC0-250V4.Set :1>.Confirm its working mode at first.2>.Press SET button enter into set mode and then press +/- button to select work mode F-1 to F-8.3>.Press SET button again when display F-1 is used to set V1 and V2. Note: V1 and V2 just be set at F-1 work mode.4>.Default display V1 value then press press +/- button to change V1.5>.Press SET button at the third time to display V2 value then press press +/- button to change V2.6>.Press SET button at the 4th time to save and exit set mode.7>.For other modes, there is no need to modify parameter values V1 and V2. After selected the mode with the +/- buttons, press the SET button again to save and exit.8>.In normal display state,keep press button ‘- ’more than 3second can turn ON/OFF display screen.5.Note:1>.It is relay switch output so it can not output voltage!2>.F-1~F8 available, F-9 and other menus not available.3>.V1 and V2 just be set at F-1 work mode.4>.It is a DC voltage detector and cannot detect AC power supply.5>.Please read use manual and description before use.6.Work Mode:1>.V1:the Lower limit voltage value.2>.V2:the Upper limit voltage value.3>.The Upper limit voltage value must be greater than the Lower limit voltage value(V2 > V1).4>.F-1:Charging Measure Mode.4.1>.Relay turn ON to start charging if the Battery Measured Value is less then the Lower limit voltage value V1.4.2>.Relay turn OFF to stop charging if the Battery Measured Value is more then the Upper limit voltage value V2.4.3>.Output keep OFF if the Battery Measured Value between V1 and V2 when the working power is first connected.5>.F-2:Discharging Measure Mode.5.1>.Relay turn ON to start discharging if the Battery Measured Value is more then the Upper limit voltage value V2.5.2>.Relay turn OFF to stop discharging if the Battery Measured Value is less then the Lower limit voltage value V1.5.3>.Output keep OFF if the Battery Measured Value between V1 and V2 when the working power is first connected.6>.F-3:Turn ON without range:6.1>.Relay turn ON if the Battery Measured Value is less the Lower limit voltage value V1 or more than the Upper limit voltage value V2. Otherwise relay turn OFF.7>.F-4:Turn ON within range:7.1>.Relay turn ON if the Battery Measured Value is between the Lower limit voltage value V1 and the Upper limit voltage value V2. Otherwise relay turn OFF.8>.F-5:Voltage Threshold Measure Mode8.1>.Relay turn ON if the Battery Measured Value is more then V1.8.2>.Relay turn OFF if the Battery Measured Value is less then V1.9>.F-6:Voltage Threshold Measure Self-lock Mode9.1>.Relay turn ON if the Battery Measured Value is more then V1. It will also maintain the output state if the voltage is lower than V1 during use. Restart the working voltage to change the output state.9.2>.Relay turn OFF if the Battery Measured Value is less then V1.10>.F-7:Voltage Threshold Measure Pulse Mode10.1>.Relay output state alternating switching ON and OFF if the Battery Measured Value is is equal to V1(+/-0.1V). Otherwise relay turn OFF.11>.F-8:Calibrate the displayed value of the measured voltage11.1>.Its calibration range is -5V to 5V.
image


image


image


image


image


image


image


image


image

Specifications

Key Features

Condition : NewType : Voltage RegulatorBrand Name : ISOrigin : Mainland ChinaFeature : Low Voltage DisconnectFeature1 : Low Voltage CutoffFeature2 : Charging Discharging Protection BoardSuitalbe for : 0-99V Lead Acid Lithium Battery Solar Panel Camper【INDEPENDENT WORKING VOLTAGE】In order to avoid consuming the voltage of the battery being measured, the device can be separately connected to another power supply as its working voltage【CHARGE AND DISCHARGE PROTECTION】You can freely set the charging or discharging mode and set . For example, when the battery voltage reaches the set voltage, the module will automatically disconnect to avoid battery over-discharging and prolong battery life【INTERZONE VOLTAGE PROTECTION】This means that you can set the number of values between which the voltage will disconnect or connect the relay【FIXED VOLTAGE MONITORING】When the measured voltage is higher than the set voltage value, the relay is connected, otherwise it will be disconnected. Alternatively, you can set it to always stay connected until you manually power off, and the relay outputs a pulse signal when the measured voltage is equal to the set voltage (up and down 0.1V)【PARAMETER】Working voltage: DC 12V; ?Measuring Range: DC 0-99.9V; ?Board size: 43.7*56mm; ?Load current:15A(Max); ?Load voltage:DC0-30V or AC0-250V4.Set :1>.Confirm its working mode at first.2>.Press SET button enter into set mode and then press +/- button to select work mode F-1 to F-8.3>.Press SET button again when display F-1 is used to set V1 and V2. Note: V1 and V2 just be set at F-1 work mode.4>.Default display V1 value then press press +/- button to change V1.5>.Press SET button at the third time to display V2 value then press press +/- button to change V2.6>.Press SET button at the 4th time to save and exit set mode.7>.For other modes, there is no need to modify parameter values V1 and V2. After selected the mode with the +/- buttons, press the SET button again to save and exit.8>.In normal display state,keep press button ‘- ’more than 3second can turn ON/OFF display screen.5.Note:1>.It is relay switch output so it can not output voltage!2>.F-1~F8 available, F-9 and other menus not available.3>.V1 and V2 just be set at F-1 work mode.4>.It is a DC voltage detector and cannot detect AC power supply.5>.Please read use manual and description before use.6.Work Mode:1>.V1:the Lower limit voltage value.2>.V2:the Upper limit voltage value.3>.The Upper limit voltage value must be greater than the Lower limit voltage value(V2 > V1).4>.F-1:Charging Measure Mode.4.1>.Relay turn ON to start charging if the Battery Measured Value is less then the Lower limit voltage value V1.4.2>.Relay turn OFF to stop charging if the Battery Measured Value is more then the Upper limit voltage value V2.4.3>.Output keep OFF if the Battery Measured Value between V1 and V2 when the working power is first connected.5>.F-2:Discharging Measure Mode.5.1>.Relay turn ON to start discharging if the Battery Measured Value is more then the Upper limit voltage value V2.5.2>.Relay turn OFF to stop discharging if the Battery Measured Value is less then the Lower limit voltage value V1.5.3>.Output keep OFF if the Battery Measured Value between V1 and V2 when the working power is first connected.6>.F-3:Turn ON without range:6.1>.Relay turn ON if the Battery Measured Value is less the Lower limit voltage value V1 or more than the Upper limit voltage value V2. Otherwise relay turn OFF.7>.F-4:Turn ON within range:7.1>.Relay turn ON if the Battery Measured Value is between the Lower limit voltage value V1 and the Upper limit voltage value V2. Otherwise relay turn OFF.8>.F-5:Voltage Threshold Measure Mode8.1>.Relay turn ON if the Battery Measured Value is more then V1.8.2>.Relay turn OFF if the Battery Measured Value is less then V1.9>.F-6:Voltage Threshold Measure Self-lock Mode9.1>.Relay turn ON if the Battery Measured Value is more then V1. It will also maintain the output state if the voltage is lower than V1 during use. Restart the working voltage to change the output state.9.2>.Relay turn OFF if the Battery Measured Value is less then V1.10>.F-7:Voltage Threshold Measure Pulse Mode10.1>.Relay output state alternating switching ON and OFF if the Battery Measured Value is is equal to V1(+/-0.1V). Otherwise relay turn OFF.11>.F-8:Calibrate the displayed value of the measured voltage11.1>.Its calibration range is -5V to 5V.

What’s in the box

1x packages

Specifications

  • SKU: GE779EA3BF9L7NAFAMZ
  • Model: SM-DSWDQ-9-21-7005
  • Production Country: China
  • Size (L x W x H cm): 20x10x20
  • Weight (kg): 0.4
  • Color: Multicolor
  • Main Material: other

Customer Feedback

This product has no ratings yet.

Battery Voltage Monitor Module DC 12V Low Voltage Cut Off Charge Discharge Protection Board for 0-99V Lead Acid Li Battery

Battery Voltage Monitor Module DC 12V Low Voltage Cut Off Charge Discharge Protection Board for 0-99V Lead Acid Li Battery

UGX 117,140
UGX 163,91829%
Questions about this product?

Recently Viewed

See All