HomeIndustrial & ScientificLab & Scientific ProductsLab Instruments & EquipmentElectrochemistry AccessoriesDC 300V ± 50A 100A 200A 400A Battery Monitor Digital Voltage Current Power Capacity SOC Hall R 12V 24V 36V 48V-2.5M Shielded CABLE
product_image_name-Generic-DC 300V ± 50A 100A 200A 400A Battery Monitor Digital Voltage Current Power Capacity  SOC Hall R 12V 24V 36V 48V-2.5M Shielded CABLE-1

Share this product

Shipped from abroad

DC 300V ± 50A 100A 200A 400A Battery Monitor Digital Voltage Current Power Capacity SOC Hall R 12V 24V 36V 48V-2.5M Shielded CABLE

UGX 237,510
UGX 409,50042%

In stock

+ shipping from UGX 44,277 to Central Business District
0 out of 5
(No ratings available)

Promotions

Delivery & Returns

Shipped from abroad 

Choose your location

Pickup Station

Delivery Fees UGX 44,277
Ready for pickup between 12 December & 17 December when you order within next 5hrs 51mins

Door Delivery

Delivery Fees UGX 46,277
Ready for delivery between 12 December & 17 December when you order within next 5hrs 51mins

Return Policy

Free return within 7 days for eligible items.Details

Seller Information

CharacterL

100%Seller Score

25 Followers

Follow

Seller Performance

Shipping speed: Excellent

Quality Score: Excellent

Customer Rating: Excellent

Product details

DC 0-300V 50A 100A 200A 400A STN LCD Hall Coulomb Counter Voltage Current Power Energy Meter Electric Vehicles Isolation

Features 1.Functional Introductions 1.Measurement of Battery percentage and remaining battery AH number. 2.Measurement of DC bidirectional current. 3.Measurement of DC bidirectional power. 4.Measurement of DC bidirectional aculative electric energy. 5.High voltage alarm flicker function. 6.Low voltage alarm flicker function. 7.High current alarm flicker function. 8.Low electricity alarm flicker function. 9.The function of reach the full voltage (this voltage can be set by youself) automatically fill the battery. 10.Zero current can be cleared. 11.Aculative energy can be cleared. 12.The backlight can be closed or opened. 13.Store data when power off. 14.Hall r isolation type measurement,more safe and reliable, easy to install. 15.Using STN full view LCD screen,clear display. 16.Super wide power supply voltage range: DC5~90V. image 3.Key Use Instructions 1.Backlight Control: In standby display, short pre “▲”key can turn on or turn off the screen backlight, backlight state power off automatically save 2.Clear Current: In standby display, long pre “▲”key about three seconds can clear current,(Note:The load must be empty when clear,otherwise it's inaccurate) 3.Clear Electric Energy: In standby display,long pre “█”key about three seconds can clear electric energy. 4.Setting Parameters: In standby display,short pre “█”key can switch the menu as follows: 【1】“AH XXX.X”the menu of battery rated capacity setting. 【2】“FU XXX.X”the menu of full power automatically filled voltage setting. 【3】“HU XXX.X”the menu of high voltage alarm setting. 【4】“LU XXX.X”the menu of low voltage alarm setting. 【5】“HA XXX.X”the menu of high current alarm setting. Battery rated capacity setting:(1)In standby display, short pre █ key,will switch to the menu “AH XXX.X”. (2)The first digit of the menu parameter will flicker,short pre ▲ key at this time digit will increasing one.When the on is not operated within five seconds, it will automatically jump to the next number to flicker.and you short pre ▲ key digit will also increasing one.And the like to set up four numbers. (3)After set up four numbers ,Long pre █ key about three seconds (Note: it is not short pre) and then release the key can save the parameters.When to save succe the screen will flicker two times. For example:When you want to set the battery rated capacity to be 20AH.You should set this menu parameter of“AH 020.0”,and long pre █ key to save parameter is finish. The battery is full of the highest electric voltage setting:(1)In standby display, short pre █ key,and switch to the menu “FU XXX.X”. (2)The first digit of the menu parameter will flicker,short pre ▲ key at this time digit will increasing one.When the on is not operated within five seconds, it will automatically jump to the next number to flicker.and you short pre ▲ key digit will also increasing one.And the like to set up four numbers. (3)After set up four numbers ,Long pre █ key about three seconds (Note: it is not short pre) and then release the key can save the parameters.When to save succe the screen will flicker two times.(Note: This voltage is suggested to be set to 0.2V le than the Coulomb's voltage when the battery is full and has not pulled out the charger.) And the like you could setting the parameters of “HU XXX.X”“LU XXX.X”“HA XXX.X”(Not:This three parameters of the factory default is “000.0” ,the factory default is to close this item's alarm function.) image image 6.Wiring Instructions There are three wires in the head of the table, as follows: 【1】The black wire is connected to the battery negative pole. 【2】The Red wire connection power supply positive pole. 【3】The Yellow wire is connected to the battery positive pole. When the measured voltage range is DC5~90V,the red and yellow wires are connected in parallel to the battery positive pole.As follows: image image 7.Precautions For Use 【1】The battery discharge ,coulomb shows display positive current.The battery charge ,coulomb shows display negative current. If not,the direction of the r is wrong. You show turn the direction of the r to another direction. 【2】The newly installed Coulomb needs to clean up the current at an empty load. 【3】The rated capacity of the battery and the maximum electric voltage of the battery must be set up. The newly installed Coulomb needs to charge the battery to full after setting up the parameters,then residual battery power can be displayed normally.

Package Included 1 x

About shping
Shping and Pack All it will be double checked and well packed before sending.It will be dispatched within 2 business days after buyers pay for the order. It usually takes about 14 to 18 working days for delivering the package to the destination(for e areas,it may take a little longer). 

Special Announcement:
Please fill in the correct and detailed consignee, address and phone number in the order. For fast and correct delivery.If you do not receive order within 30 working days,please feel free to contact Customer Service before leaving Negative and Neutral Feedback, we will do our best to help you resoe the problem.TaxNo, you will only pay what is quoted as total cost at checkout, no more. You are not expected to pay any additional duties or taxes. If you are asked by Customs or our logistic partner to pay duties, please contact our Customer Service .

Your 100% satisfaction is very ant to us
If the product is not on good condition, You can return this product within 14 working days, please contact customer service center before returning.FeedbackYour satisfaction is our first priorityIf you receive the order and it is in good condition,we would be grateful if you would leave us 5 star Positive Feedback for the transaction.

Specifications

Key Features

  • DIY Supplies:ELECTRICAL
  • Certification:NONE
  • Origin:Mainland China
  • Type:DC 300V
  • Output Type:0-300V
  • Size:S
  • Model Number:50A-400A
  • Style:DC METER

What’s in the box

1X DC 300V ± 50A 100A 200A 400A Battery Monitor digital Voltage current power Capacity SOC Hall r 12V 24V 36V 48V

Specifications

  • SKU: GE779IP4185UCNAFAMZ
  • Model: CCHAyiqipeijian559
  • Production Country: China
  • Size (L x W x H cm): 10*10*10
  • Weight (kg): 0.2
  • Color: 2.5M Shielded CABLE

Customer Feedback

This product has no ratings yet.

DC 300V ± 50A 100A 200A 400A Battery Monitor Digital Voltage Current Power Capacity  SOC Hall R 12V 24V 36V 48V-2.5M Shielded CABLE

DC 300V ± 50A 100A 200A 400A Battery Monitor Digital Voltage Current Power Capacity SOC Hall R 12V 24V 36V 48V-2.5M Shielded CABLE

UGX 237,510
UGX 409,50042%
Questions about this product?

Recently Viewed

See All