This website uses cookies
This website uses cookies. For further information on how we use cookies you can read our Privacy and Cookie notice
This website uses cookies. For further information on how we use cookies you can read our Privacy and Cookie notice
Shipped from abroad
Free return within 7 days for eligible items.Details
CharacterL
100%Seller Score
25 Followers
Shipping speed: Excellent
Quality Score: Excellent
Customer Rating: Excellent
Descrtion: It provides 5 kinds of functions for users to choose, to meet more application needs. You can set the voltage upper and lower voltage limits. Measuring range 0-100V DC, measuring accuracy ±0.1V. You can set the automatic power saving function. All set parameters can be automatically saved, the setting contents won't be lost when blackout occurs. Specification: Working voltage: 5V, 12V, 24V (nominal voltage should not exceed ±10%). Size(L×W×H): Approx. 67×44×20mm/ 2.64×1.73×0.79 inch Module voltage inputs: a 4-wire interface, all the terminals are the interface. DC+: DC power positive DC-: DC power supply negative V+: measuring voltage positive V-: measure negative voltage Parameter setting: Key: [SET] [SWI], [+] and [-], the keys have short and long pre, short pre means pre the on le than 1 seconds, long pre means pre the on more than 1 seconds. User parameter: there are 6 kinds of parameters can be set, they are P0-P5 [P-0]: Function No.: F-01 to F-05 [P-1]: V1 voltage setting: 00.0V to 99.9V [P-2]: V2 voltage setting: 00.0V to 99.9V [P-3]: Voltage setting: fing display the current voltage, pre + or -,setting the voltage. [P-4]: T1 delay setting: 00.0 seconds to 99.9 seconds,T1 time until to detect the pull condition, the relay pull in. [P-5]: T2 delay setting: 00.0 seconds to 99.9 seconds,T2 time until to detect the disconnect condition, the relay disconnect. Types of function: Voltage measurement: select this function, the relay will not move, the digital display of the current measurement voltage; Charging monitoring: When the measured voltage is lower than the lower limit voltage, the relay pulls above the upper limit voltage, the relay is disconnected; Discharge monitoring: When the measured voltage is higher than the upper limit voltage, the relay pulls, below the lower limit voltage, the relay is disconnected; Interval within the pull: When the measured voltage between the upper and lower limits, the relay pull, the other case the relay is off; Interval outside the pull: When the measured voltage is lower than the lower limit voltage, or the measured voltage is higher than the upper limit voltage, the relay pull; other cirstances the relay is disconnected. Package Included: 1 * DVB01 Digital Display Voltage Measuring Module
About shping
This product has no ratings yet.