Shipped from abroad
Free return within 7 days for eligible items.Details
herhrehb
60%Seller Score
Be the first to follow
Shipping speed: Very Poor
Description:
1. Waterproof case
2. Working voltage 8-80V
3. Suitable for all battery types
4. Power-off memory two-way test
5. Low energy consumption sleep 60uA
6. Battery symbol: percentage / voltage display; used to detect various battery residual capacity, voltage and current.
7. It is suitable for all kinds of instruments, measuring equipment, mobile and portable equipment, sweeping machines, balance cars, battery carts, etc.
8. s: rated capacity: 999 mah
Applicable temperature: -10-40 °C
Applicable battery: lithium battery, lead acid battery, etc.
Working power consumption: 12mA
Using steps:
1. Connect and chethe current:Power on after complete the connection as shown,the screen should display capacity percentage. If the screen has no response,please chethe connection. Then charge or discharge the battery, and chewhether the display current is equal to the actual current. If the deviation is large please chethe connection.
2.Capacity reset:On first use,the percentage and capacity are not the actual value,you should reset the capacity:discharge the battery totally and hold the''
3.Cheand reset the actual capacity:If you find the display capacity don't match the actual capacity,please cheand reset the actual capacity:discharge the battery totally and hold the ''
Package Include:
1 x DC 8-80V 50A 100A 350A TR16 Coulomb Counter Meter
We need a shielded wire and a ordinary wire 0.3-0.75 mm2.One end of the ordinary wire connects to positive of battery,another end connects to B+ of sampler any one is ok.The B- of sampler connects to B- of battery. P- of sampler connect to P- of output. Finally connect sampler to coulometer by the shielded wire.Notice: The diagram is not equal proportion
Attention: Please connect as shown strictly. The sampler must be connected to the negative circuit, it is forbidden to connect to the positive circuit. If you want to extend the shielded wire,you must use 4 lines of same specification.
First,open a round holes of 54.5mm on the panel of the equipment. Then install the coulometer from the front of the panel. Finally,tighten the bracket on the back. As shown below:
This product has no ratings yet.