DC-DC 5A Digital LED Drive Lithum Battery Charger Module CC/CV USB Step Down Buck Converter With
Descrtion:
Specifications:
1.Input voltage range:5-36VDC
2.Output voltage range:1.25-32VDC adjustable
3.Output current: 0-5A
4.Output power: 75W
5.High efficiency up to 96%
6.Built in thermal shutdown function
7.Built in current limit function
8.Built in output short protection function
9.Input re polarity protection: None (if required, high current diode in series with the input).
10.L x W x H =68.2×38.8×15mm
11.Weight: 39g
Note:
1.When you use the product, the module inputs and outputs to be isolated from ground.
2.USB output voltage is consistent with the module, not a fixed 5V output. When charging for digital equment, make sure USB output voltage is 5V.
3.Some customers report: “The module can not adjust the output voltage is always equal to the input voltage.” When you encounter this problem, please counterclockwise rotation of the “voltage potentiometer” 10 laps or more, then use the module you can adjust the output voltage. Because the factory default output voltage of about 20V.
Application :
1.Use as a step-down modules with overcurrent protection
Usage:
(1) Adjust the right on so that “OUT” LED lighted, Digital meter shows the value of output voltage ,adjust the “voltage potentiometer” so that the output voltage reaches the value you want.
(2) Adjust the right on so that Digital meter shows the value of output current;Wire shorted output terminal, then adjust the “current potentiometer” so that the output current reaches a predetermined overcurrent protection value. (For example, the Digital meter displays the current value of 4A, then you can use the module to a maximum current of 4A)
(3) Connected to the load.
2.Use as a battery charger
Usage:
(1) Make sure you need to charge the battery float voltage and charging current; (if lithium parameters 3.7V/2200mAh, then the float voltage is 4.2V, the maximum charging current 1C, ie 2200mA)
(2)Under no-load conditions, adjust the “Voltage potentiometer” so that the output voltage reaches the float voltage; (if to 3.7V rechargeable lithium battery, the output voltage can be adjusted to 4.2V)
(3)Adjust the right on so that Digital meter shows the value of output current;Wire shorted output terminal, then adjust the “current potentiometer” so that the output current reaches a predetermined Charging current value.
(4)Charge turn lamp current factory default is 0.1 times the charging current; (Battery during charging current is gradually reduced, if the charge current setting is 1A, then when the charge current is le than 0.1A, blue lights turned off, the green light is on, which means that the battery is fully charged)
(5)connected to the battery charge.
(1,2,3,4 steps as: Output is unloaded, do not connect the battery)
3.Use as a LED constant current driver module
Usage:
(1)Adjust the “voltage potentiometer” so that the output voltage reaches the value you want.
(2)Adjust the right on so that Digital meter shows the value of output current;Wire shorted output terminal, then adjust the “current potentiometer” so that the output current reaches a predetermined LED operating current.
(3)Connect LED, work.
(1,2 steps as: Output is unloaded, do not connect LED)
and calibration method:
Module with manual calibration function can correct display precision voltage and current, if you think the current voltage and current accuracy to meet the requirements, do not perform the following operations.
(1) Output voltage calibration steps
Step 1, adjust the right on so that “OUT” LED lighted, Digital meter shows the value of output voltage; Pre the right on for more than 2 seconds, release, Digital meter and “OUT” LED fes in synchronization so that you enter the output voltage calibration mode.
Step 2, pre the right on (normal speed), the voltage value is adding up a unit; Pre the left on, minus a unit; Due to a unit is le than 0.1V, the minimum voltage display to 0.1V, so you need to continuously pre 1-5 times to see the change 0.1V, how many times change 0.1V by preing the key, depending on the current display voltage, the higher the voltage, the fewer the number of pre.
Step 3, pre the right on for more than 2 seconds, release, to exit the output voltage calibration mode. All parameters set to automatically power down to save.
(2) Input voltage calibration steps
Step 1, adjust the right on so that “IN” LED lighted, Digital meter shows the value of input voltage; pre the right on for more than 2 seconds, release, Digital meter and “IN” LED fes in synchronization so that you enter the input voltage calibration mode.
Steps 2 and 3, consistent with the output voltage calibration method.
(3)Output current calibration steps
Step 1, adjust the right on so that Digital meter shows the value of output Current. Pre the right on for more than 2 seconds,release, Digital meter fes in synchronization so that you enter the output current calibration mode.
Step 2,Connected to the load, in series, adjust the right and left on to change the display of digital meter, so that is consistent with the display .
About shping