This doent describes the specification of the PZEM-013/015 DC multifunction battery , this meter is mainly used to test all kinds of battery's voltage, discharge current, discharge power, discharge impedance, internal resistance, capacity, dump energy, energy consumption and running time, and display the measurement data through LCD screen. PZEM-013: Measuring Range 10A (Built-in Shunt) PZEM-015: Measuring Range 300A (use external shunt, can matched with 50A, 100A, 200A, 300A four kinds of shunt). 1. Function descrtion 1.1 Voltage 1.1.1 Measuring range: 0-200V. (when the test voltage is le than 8V, please use the independent power supply mode) 1.1.2 Display format: le than 10V display as: 9.99V le than 100V display as: 99.9V greater than 100V display as: 199V 1.1.3 Minimum resolution:0.01V 1.1.4 The starting test voltage: 0.05V 1.1.5 Measurement accuracy:1% 1.2 Current 1.2.1 Measuring range: 0-10A. (Type: PZEM-013) 0-300A(Type: PZEM-015) can set 50A, 100A, 200A,300A four range depend on the external shunt, the factory default is 100A. 1.2.2 Display format: le than 1A display as: 999mA < 10A display as: 9.99A <100A display as: 99.9A ≥ 100A display as: 199A 1.2.3 Minimum resolution: 1mA 1.2.4 The starting test current: 10mA(Type: PZEM-013) 20mA(Type: PZEM-015) 1.2.5 Measurement accuracy:1% 1.3 Power 1.3.1 Measuring range: 0-2000W (Type: PZEM-013) 0-60000W(Type: PZEM-015). 1.3.2 Display format: < 10W display as: 9.99W < 100W display as: 99.9W < 1000W display as: 999W < 10000W display as: 9.99kW ≥ 10000W display as: 19.9kw 1.3.3 Minimum resolution: 0.01W 1.3.4 The starting test power: 0.1W (Type: PZEM-013) 0.2W (Type: PZEM-015) 1.3.5 Measurement accuracy:1% 1.4 Impedance Impedance=Voltage/ Current 1.4.1 Measuring range: 0-1000 ohm 1.4.2 Display format: < 100 ohm display as: 99.9 ohm ≥ 100 ohm display as: 999ohm When over the test range or the current is zero, it display "---" 1.4.3 Minimum resolution: 0.1ohm 1.4.4 Measurement accuracy:1% 1.5 Internal Resistance Internal resistance= (Full voltage - Bring load voltage) / Bring load current, when the bring load voltage is larger than the maximum voltage, the internal resistance is zero. 1.5.1 Measuring range: 0-999 milliohm 1.5.2 Display format: 999 milliohm , when over the test range or the current is zero, it display "---". 1.5.3 Minimum resolution: 1 milliohm 1.5.4 Measurement accuracy:1% Note: Before you test the internal resistance, you should preset the full voltage depend on the battery type, after it is fully charged you can use it to test; if you do not fully charge it, you can set the battery without load voltage is the full voltage, then test; the internal resistance is not a fixed value, the more the battery discharged, the bigger the resistance. 1.6 Capacity 1.6.1 Measuring range: 0-1000AH 1.6.2 Display format: < 1AH display as: 999mAH < 10AH display as: 9.99AH < 100AH display as: 99.9AH < 1000AH display as: 999AH 1.6.3 Minimum resolution: 1mAH 1.6.4 Measurement accuracy:1% Note: Battery capacity testing is a ulative proce of discharge current versus time, it need some time, the time is depend on the discharge current; before you test the capacity, you should preset the full voltage and the cut-off voltage depend on the battery type, after it is fully charged you can use it to the discharge test; When the dump energy display blank, it means the discharge is over, this capacity display value is the battery's capacity. 1.7 Dump energy Dump energy is display via the battery symbol, totally 10 grids, every grid present 10% energy. Dump energy is calculated via the current battery voltage value, before test you should preset the full voltage and the cut-off voltage depend on the battery type; every grid voltage = (the highest voltage - the lowest voltage) / 10. 1.8 Aculate energy consumption 1.8.1 Measuring range: 0 - 9999kWh 1.8.2 Display format: < 1kWh display as: 999Wh < 10kWh display as: 9.99kWh < 100kWh display as: 99.99kWh < 1000kWh display as: 999.99kWh ≥ 1000kWh display as: 9999kWh Over the test range will become zero. 1.8.3 Minimum resolution: 1Wh 1.8.4 Measurement accuracy:1% Note: 1Wh=0.001kWh=0.001 Kilowatt 1.9 Running time 1.9.1 Measuring range: 0 ~ 999 hour (without load the time will not aculate) 1.9.2 Display format: 0:00:00 ~ 999:59:59 Over the test range will become zero. 2. Operating Instructions 2.1 Setting the full and cur-off voltage
2.1.1 Set the full voltage: Step 1: In the normal display interface(like fig. 1), long pre the on until the LCD screen display the interface like fig. 2, then release the on Step 2: SET character blink present it is the setting status of full / cut-off voltage, long pre the on until the LCD screen display the interface like fig. 3, then release the on. Step 3: At this time, the battery symbol display full grids energy means the full voltage setting status, factory default the full voltage is 020.0V, the numerical code circulation fing from the low bit to the high bit show that the current setting digit, short pre to set the digit; please pay attention that, as the full voltage setting value has 4 digit, but the numerical code has only 3 digit, So the setting is divided into two parts: low bit (fig. 3) +high bit (fig. 4). For example, the default full voltage is 020.0V, then the display state is 20.0V to 020V low and high cyclic switching display. If you need to set the full voltage is 199.0V, then please set the low bit to 99.0V, when the cycle reaches the high bit, it will display 099V, and only the highest zero bit flicker to prompt it can be setted. Setting the high bit to 199V represents the full voltage is 199.0V. 2.1.2 Set the Cut-off voltage: Step 1: After you set the full voltage, loner pre the on until LCD shows the interface of Fig. 5, then release the on; Step 2: At this time, the battery symbol shows the zero-grid to indicate the cut-off voltage setting state, the default cut-off voltage is 016.0V, the setting method is the same as above; the cut-off voltage is 0.8 times of the full voltage by default, after setting the full voltage, the cut-off voltage is automatically generated in the relationsh of 0.8 times; otherwise, you can reset it; After all the above settings are completed, long pre the on until the settings are saved and exit the setting status, restore the normal display interface. 2.2 Current range setting (Only for PZEM-015) Step 1: In the normal display interface, long pre the on until the LCD shows the interface of Figure 2, then release the on, short pre the on again switch to the interface to Figure 7, it indicates that this state is the current range setting state. Step 2: Longer pre the on until the LCD shows the interface of Figure 8, then release the on, short pre the on again to switch the current range. This meter provides four current ranges, factory default is 100A, choose the corresponding range according to the shunt. Step 3: After the current range setting is completed, long pre the on until the settings are saved and exit the setting status, restore the normal display interface. 2.3 Clear the Energy Step 1: In the normal display interface, long pre the on until the LCD shows the interface of Figure 2, then release the on, short pre the on again switch to the interface to Figure 9, it indicates that this state is the clearing energy setting state. Step 2: Longer pre the on until the data has been cleared and exit the setting status, restore the normal display interface. 2.4 Clear the capacity Step 1: In the normal display interface, long pre the on until the LCD shows the interface of Figure 2, then release the on, short pre the on again switch to the interface to Figure 10, it indicates that this state is the clearing capacity setting state. Step 2: Longer pre the on until the data has been cleared and exit the setting status, restore the normal display interface. 2.5 Clear the running time Step 1: In the normal display interface, long pre the on until the LCD shows the interface of Figure 2,then release the on, short pre the on again switch to the interface to Figure 11, it indicates that this state is the clearing running time setting state. Step 2: Longer pre the on until the data has been cleared and exit the setting status, restore the normal display interface. 2.6 Working mode This meter has two modes: normal display mode and dormant mode. In normal display mode, short pre the on to enter the dormant mode, in order to reduce the whole hine power consumption, the backlight and LCD display will be turned off in dormant mode. In dormant mode, short pre the on will switch to the normal display mode. Note: The meter will stop all measurement functions in dormant mode, so please do not switch to dormant mode if normal measurement is performed. 3. Wiring Diagram 4.Dimension Figure (mm) 5. Matters needing attention 5.1 This module is suitable for indoor, please do not use outdoor. 5.2 Applied load should not exceed the rated voltage, current. 5.3 Wiring order can't be wrong. 6. Other specification 6.1 LCD full display figure 6.2 Power consumption Normal working state: 0.03-1.2 W Sleeping state: 0.5mW-0.5W The power consumption is related to the test voltage value, the higher the voltage,the greater the power consumption 6.3 Working temperature -20C ~+60C
About shpingThis product has no ratings yet.
Subscribe to our newsletter
and be the first one to know about our amazing deals!