Main technical parameter
l Rated voltage 230 frequency 50/60Hz
l Rate current 1A-80A,Adjustable(default 63A),
l undervoltage action cut off value:140-210V, adjustable(default 160V)
l Over voltage action cut-off value:230-300V, adjustable (default280V)
l Power recovery delay after power fai :5s
l Range of time delay: ls-600s adjustable,(default:30s)
l Electrical hinery life: minimum 50000 times
l Exterior dimension: 85x36x66mm
l Overvoltage and undervoltage restore value is 5V of the set value and overcurrent restore is 1A le than set value
l Please note the mode of up in and down out or down in and up out in ordering.
l Rated operation characteristics and operate time 10A,20A ,32A, 40A,50A ,63A.
l Rated turn on capacity protection device can be reliably connected and disconnected from the current value after continuous operation for long time Rated current priority value: 10A,20A ,32A, 40 X 50A,63A,80A.
l Rated limit overcurrent 63A,80A
Product setting
Click the SET key to enter the setting status
Over voltage setting
Please pre up and down key for revise if the overvoltage setting digital display overvoltage value indicator fes ,The default is 280V, it will progreively increase or decrease progreively by 1v for each pre ,its will progreively increase of decrease progreively by 10v after long pre up and under key
Under voltage setting
Please pre up and down key for modify within the range of 140-210V if the undervoltage setting digital display under voltage value indicator f, default is 160V it will progreively increase or decrease progreively by 1v for each pre ,its will progreively increase of decrease progreively by 10v after long pre up and under key
Over current setting
please pre up and down key for modify ,with range of 1-80A ,default is 20A. 1A for each pre un and down key, 10A for long pre up and down key
Delay setting
Please pre up and down key for modify of 1 S -600S if the digital dispaly delay value indicator fes. The default is 30s. 1s for each pre un and down key, 10s for long pre up and down key
Setting confirmation
Long pre SET key for 5 seconds to return to display input voltage value after the setting of all parameters. The setting is completed and saved
Function of ON/OFF key
The product will forcibly cut off the output relay and disconnect load to facilitate the maintenance of the circuit after preing power on, the product will restore output after delay of 5s and work normally after preing the key again.