This website uses cookies
This website uses cookies. For further information on how we use cookies you can read our Privacy and Cookie notice
This website uses cookies. For further information on how we use cookies you can read our Privacy and Cookie notice
Shipped from abroad
Free return within 7 days for eligible items.Details
Sweet Memories
74%Seller Score
18 Followers
Shipping speed: Good
Quality Score: Excellent
Customer Rating: Poor
All our products are devised and produced by ourselves. So believe that our quality, price and service will definitely give you satisfaction!
Big Retailers We have big retailers in Ukraine, if it is not inconvenient for you to order the products from our China warehouse, you can contact us to get the way to buy in local store.
Technical Support
If you have any questions about our products, welcome to contact us in these ways,for now we support Tencent QQ group, WeChat group and WhatsApp, here is the contact information. QQ Group:550112838 WeChat:15868147353 WhatsApp:+8615868147353Constant Voltage Constant Current
Programmable Control Supply Power Module
Product model: DPS3012
File download : 1. DPS3012 operation instruction: A:Main download link: http://www.mediafire.com/folder/huu7cydgcw9i3/DPS3012_file B:Baup download linlk: https://drive.google.com/open?id=1k0RhDHxAUBkZuw5jEdi6GqBc6nFDDtzJ 2. Recommended supporting case: Metal case, please choose “choice 2” (it is suitable for DPS3012 ): https://www.aliexpre.com/item/1000004752402.html aemble instruction: https://drive.google.com/open?id=1s4kWis48ZUtR9vwmHsqVpvsIXaYJicca Pay attention before buying: 1, Output must be used isolated, not in series or on parallel, otherwise it will be burnt. 2, if you connect inductive load (such as motor), the max working current is 1/3 of range. don't over it. 3. before using, please connect all wire well first, then turn on the input power supply, not turn on the input power supply first, then connect the wire. Otherwise it will cause the fuse and MOS damaged. 4, when you get the product in the first time, please don't use your hands to touch the components, because human static electricity can damage some chs. 5.You must make sure that the input voltage is 1.1 times higher than output voltage. Under large current circumstances, pay attention to heat elimination. 6, if you use AC-DC converter or transformer coil, please add rectifier (rectifier bridge) and filter (more than 4700uf filter ). If input power supply is unstable, please add LC, L is over 47uf, C is over 2200 uf. 7.When the current is more than 10A or the temperature is more than 45 °c , the fan will begin to work. when the temperature is more than 65°c, the module will stop working 8. for input power supply , there is a recommended one S-400-36V, it is just recommened, not provide any technical support , please contact that seller ,when you use this for DPS3012, please adjust to lower 40V output to use , link: https://www.aliexpre.com/item/32882215425.html , please choose 400w/36VTechnical parameters
Input voltage range: 6.00-40.00V Output voltage range: 0V-32.00V
Output current: 0-12.00A Output power range: 0-384W
Product Weight: about 225g Display module size: 79*43*41(mm) (L*W*H)
Open size: 71mm*39mm Power module size: 93*71*41(mm) (L*W*H)
Length of connecting line: 200mm Fixed hole center distance: 86mm, 64mm
Output voltage resolution: 0.01V Output current resolution: 0.01A
Output Voltage accuracy: ± (0.5% + 3 digit) Output Current accuracy: ± (0.5% + 5 digits)
DPS 3012 Customer feedba video : 1.https://www.youtube.com/watch?v=vcI_NJ_kcPI 2.https://www.youtube.com/watch?v=IgLjXuA64Fs DPS3012 power test + chs: https://www.youtube.com/watch?v=q1wy0gzXgGo DPS 5005 tear down video: https://www.youtube.com/watch?v=BklUuj5-j10The correlation table :
DP series (DP50V5A and DP30V5A (Simple LED version DP30V5AL) ) ;
DPS bu power supply series (DPS3003,DPS3005,DPS5005,DPS3012, DPS5015,DPS5020);
DPH bu-boost power supply series (DPH3205 and DPH5005);
If you want to seeDP50V5Acli this https://www.aliexpre.com/item/32596330856.html
If you want to seeDP30V5Acli this https://www.aliexpre.com/item/32613371214.html
If you want to seeDP30V5A-Lcli this https://www.aliexpre.com/item/32639806678.html
If you want to seeDPS3003cli this https://www.aliexpre.com/item/32685187020.html
If you want to seeDPS3005cli this https://www.aliexpre.com/item/32684316119.html
If you want to seeDPS5005cli this https://www.aliexpre.com/item/1000004290003.html
If you want to seeDPS3012cli this https://www.aliexpre.com/item/32685179404.html
If you want to seeDPS5015cli this https://www.aliexpre.com/item/32702714880.html
If you want to seeDPS5020cli this https://www.aliexpre.com/item/32821185351.html
If you want to seeDPH3205cli this https://www.aliexpre.com/item/32762131242.html
If you want to seeDPH5005clithis https://www.aliexpre.com/item/32840324731.html
If you want to seeDPS8005cli this https://www.aliexpre.com/item/32849962454.html
Digital Power Supply related series of products:
DPS3005
DPS5005
DPS5015
DPS5020
DPH5005
DPS8005
DP50V5A
DP30V5A
DPS3003
DPS3012
DPH3205
DPS3005
DPS3005-USB
DPS3005-USB-BT
DPS5005
DPS5005-USB
DPS5005-USB-BT
DPS5015
DPS5015-USB
DPS5015-USB-BT
DPS5020
DPS5020-USB
DPS5020-USB-BT
DPH5005
DPH5005-USB
DPH5005-USB-BT
DPS8005
DPS8005-USB
DPS8005-USB-BT
Picture
difference
between
DP,DPS
and DPH
1.DPS series are updated version. Panel is different. In DPS series, we change the M1/↑and M2/↓ into V/↑and A/↓. You can pre those button
Set the voltage and current fast. We add a new function “set default boot open or close output”
Others are not changed.
2.All those power supply can charge the battery directly, don't need external diode. When charging battery, don’t connect battery polarity
rely , otherwise, power parts will bunt.
Find the difference between DPS and DP see this video https://www.youtube.com/watch?v=ptt931rrXo8
3.DP power supply and DPS power supply are all bu (step-down) converter. But DPH3205 and DPH5005 is bu-boost (step-down and step-up) converter .
4. DPS3005, DPS5005 DPS5015, DPS5020, DPH5005 and DPS8005 have communication version. You can connect PC and use upper computer
Communication function
NO
NO
NO
NO
NO
Ye
Ye
Ye
YES
YES
YES
Working mode
Bu
Bu
Bu
Bu
Bu-
Boost
Bu
Bu
Bu
Bu
Bu-
Boost
Bu
Input voltage
6-55V
6-40V
6-40V
6-40V
6-40V
6-40V
6-55V
6-60V
6-60V
6-50V
10-90V
Output voltage
0-50.00V
0-32V
0-32V
0-32V
0-32V
0-32V
0-50V
0-50V
0-50V
0-50V
0-80V
Output current
0-5.000A
0-5.000A
0-3.000A
0-12.00A
0-5.000A
0-5.000A
0-5.000A
0-15.00A
0-20.00A
0-5.000A
0-5.000A
Output power
0-250W
0-160W
0-96W
0-384W
0-160W
0-160W
0-250W
0-750W
0-999.9W
0-250W
0-400W
Voltage resolution
0.01V
0.01V
0.01V
0.01V
0.01V
0.01V
0.01V
0.01V
0.01V
0.01V
0.01V
Current resolution
0.001A
0.001A
0.001A
0.01A
0.001A
0.001A
0.001A
0.01A
0.01A
0.001A
0.001A
Product size
79*43*38mm (display part )-93*71*41(power board )
Only DPS5020/DPS5015/DPS3012/DPH5005/DPH3205 has power board
screen
Color LCD
Fan
NO
NO
NO
YES
YES
NO
NO
YES
YES
YES
NO
Charge the battery
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
Function
·Preset output voltage / current(in two places by SET KEY)
·Preset protection value
·6 running status icon
·Key lo
·Data setting and store the specified data group
·Store shortcut storage value
·Exact shortcut M1 or M2 or specified data group
·Adjust LCD brightne
·Open or close output
·10 data group
·Preset output voltage / current(in two places, by V,A button and SET KEY)
·Preset protection value
·6 running status icon
·Key lo
·Data setting and store the specified data group
·Store shortcut storage value
·Exact shortcut M1 or M2 or specified data group
·Adjust LCD brightne
·Open or close output
·10 data group
·Set default boot open or close output
General Information
IN+: Input positive IN-: Input negative:
OUT+: Output positive: OUT-: Output negative
Note: Input voltage range is DC 6-40V and 40v is the limit voltage; please leave a room to use. Or else it will be burnt. The input must be DC power supply, not AC 220V, or else it will be burnt too. Though this module has re connection protection and output short circuit protection, you can muse be in strict accordance with connection descrtion to connect. If you connect the supply power with output, the module will be burnt.
Panel descrtion
1-Voltage setting/Page up to choose/Shortcut extract M1 data group
2-Data setting/ Extract value of the specified data group/Store value into the specified data group
3-Current setting/Page Down to choose/Shortcut extract M2 data group
4-1.44 inch color LCD screen
5-Coding potentiometer/Data adjustment/Lo all button
6-Open or close output
Display interface descrtion
7-The preset value of output voltage
8- The actual value of output voltage
9-The actual value of output current
10-The actual value of output power
11-The actual value of input voltage
12-The preset value of output current
13-Key lo or unlo prompt
14-Output normal or not prompt
15-Constant voltage and constant current status prompt
16-Data set prompt
17-Open or close output prompt
18-Preset output voltage
19-Preset output current
20-Preset over- voltage
21-Preset over-current
22-Preset over-power
23-Preset screen brightne
24-Preset data set
25-The actual value of output voltage and output current
Operating instructions
When connect the power supply, the screen shows welcome window firstly and then comes into main interface. On the main interface, the output set voltage value and the output set current value is on the top of the screen. The big font value on the left are the current real output voltage, the current real output current and the current real output power. Input voltage is on the bottom of the screen. There are some running status icons on the right of the screen, key lo icon, abnormal output status icon, constant voltage and constant current icon, data set t icon and opening or closing output icon.
Set the output voltage and output current on the main interface.
Pre V/↑key shortly, you can enter into voltage setting status. Then pre the coding potentiometer, and then enter to adjust the numerical value. Pre coding potentiometer to enter into the status of adjusting the numerical value you want to adjust. Turn coding potentiometer to adjust the numerical value. Turn by clowise rotation to increase the numerical value; Turn by counterclowise to decrease the numerical value. If you want to exit adjusting the numerical value, pre shortly V/↑. In the same time the preset value will be stored. Or you can do nothing in one minute, the status will be automatically existed and the preset will be stored too. You can pre A/↓to set the output current by the same way.
Set the data on the data setting interface
On the main interface, you can pre SET key shortly to enter into data setting interface. On the data setting interface, pre shortly V/↑or A/↓ to page up or page down to U-SET or I-SET, and then set the output voltage and output current by same way used in the main interface .
Set the protection value.
Page up or page down to S-OVP, S-OCP or S-OPP place to set over-voltage value , over-current value and over-power value correspondingly; when the value is up to the setting value, output will be closed. And then pre shortly the coding potentiometer to enter into the status of adjusting the numerical value you want to adjust. Turn coding potentiometer to adjust the numerical value. If you want to exit adjusting the numerical value, pre shortly SET key.
Adjust the brightne of screen.
Page up or page down to B-LED, and then pre shortly the coding potentiometer to enter into the status of adjusting the brightne of screen. Turn coding potentiometer to adjust the numerical value you need. If you want to exit adjusting the numerical value, pre shortly SET key. There are six brightne levels of LCD screen, 0-5 level. Rank 0 is the darkest; rank 5 is the brightest. You can choose what you like.
Data setting and store the specified data group.
Page up or page down to M-PRE, and then pre shortly the coding potentiometer to enter into the status of choosing the data groups. Turn coding potentiometer to choose the data group you need to view. Then the data group you need will be displayed. And then pre the coding potentiometer to enter into status of changing output state. Turn coding potentiometer to choose ON or OFF. When choose ON, the data group is extracted and the output status remain the same. When choose OFF, the data group is extracted and the output is closed. If you want to exit choosing data set, pre shortly SET key. Then pre shortly V/↑or A/↓ to page up or page down to other place to adjust the data you need. After data setting done, keep preing SET key more than 2s, all the data you set are automatically stored into the specified data group. In the same time, you can see the group number on the right of screen. At last you can pre shortly SET key ba to the main interface.
Set default boot open or close output
Page up or page down to S-INI, and then pre shortly the coding potentiometer to enter into the setting status. Set ON, default boot open; set off, default boot close.
Function descrtion.
Open or close the output .
You can pre ON/OFF key to open or close the output on any interface.
Lo the button to avoid wrong operation.
On the any interface, you can keep preing coding potentiometer more than 2s, all buttons are loed. You can see the key lo icon on the right of screen. If you want to unlo all buttons, keep preing coding potentiometer more than 2s, all buttons are . The key unlo icon will be displayed on the right of screen.
M0-M9 ten groups data group
M0 group is the boot default data group. When you extract the data group you need, this data group will cover M0 data group and be automatically stored on M0 data group.
Extract Shortcut storage data group M1 or M2.
On the main interface, keep preing V/↑or A/↓ more than 2s, you can extract Shortcut storage data group M1 or M2 quily. In the same time the corresponding data group number will displayed on the right of the screen.