Constant Voltage Constant Current
Programmable Control Supply Power Module
Product model: DPS5020
Pay attention before shping :
1, there are 3 version , No communication version , communication + USB version , communication + USB+ BT (bluetooth).
2,For no communication version , there is no commnunication program and hardware to support, not any communication function, can't be updated.
3, This is file for upper computer installation and , you can download https://www.mediafire.com/folder/3iogirsx1s0vp/DPS_communication_upper_computer
4. DPS5020 performance test: https://www.youtube.com/watch?v=igY0s4drtlc&t=157s
5. Upper computer installation, connection by USB and Bluetooth video : https://www.youtube.com/watch?v=7BL6KmY4x-A&google_comment_id=z13qi1kinrzeu1sj104cj3syeyfgu33piys0k&google_view_type#gpluscomments
Very ant: 1.Before buying this product, please download the upper computer and test, if it fits your computer , you can buy
2 . the upper computer only support For Win7 and above
General Information
The constant voltage and constant current programmable control power supply module put the collection of analog integration and digital control functions in one. Its adjustable output voltage range is 0-50.00V, step by 0.01V. Its adjustable output current range is 0-20.00A, step by 0.01A. This module has power-down stored function and can store 10 groups preset value. And it also has the function of extracting quily two groups stored value. Compared with the traditional analog power supply, it is more convenient to quily extract the voltage or current required. LCD display on the module has the function digital and . You can view the preset voltage, input voltage, output voltage, the preset current, output current, output power, etc. on the output state remind area, you can see that output opens or not, the state of constant voltage and constant current, output is normal or not, the key is loed or not, and the current data groups that is being used. On the setting data interface, you can adjust overvoltage value, overcurrent value, over-power value, data set and LCD brightne. This module has many advantages, small size, advanced function, good visual effect, high operability, high-precision, being used independently, being inset into the device and been widely applied.
Technical parameters
Input voltage range: 6.00-60.00V Output voltage range: 0V-50.00V
Output current: 0-20.00A Output power range: 0-1000W
Product Weight: about 222g Display module size: 79*43*41(mm) (L*W*H)
Open size: 71mm*39mm Power module size: 93*71*41(mm) (L*W*H)
Length of connecting line: 200mm Fixed hole center distance: 86mm, 64mm
Output voltage resolution: 0.01V Output current resolution: 0.01A
Output Voltage accuracy: ± (0.5% + 1 digit) Output Current accuracy: ± (0.5% + 2 digits)
NOTE:
1, when you get the product in the first time, please don't use your hands to touch the components, because human static electricity can damage some chs.
2.You must make sure that the input voltage is 1.1 times higher than output voltage. Under large current circumstances, pay attention to heat elimination.
3. When the current is more than 10A or the temperature is more than 45 °c , the fan will begin to work. when the temperature is more than 65°c, the module will stop working
4, if you use AC-DC converter or transformer coil, please add rectifier (rectifier bridge) and filter (more than 4700uf filter ). If input power supply is unstable, please add LC, L is over 47uH, C is over 2200 uf.
Test video from customer feedba of YouTube:
This the most comprehensive analysis for DPS5015 :http://lygte-info.dk/review/Power%20DPS5015%20UK.html
My YouTube channel: https://www.youtube.com/channel/UCy73jJ5-ZqhPzT7wJ6KTIaw
DPS5015: rple test: https://www.youtube.com/watch?v=WpbkxL0p7u8&list=PLNcr2Rj_07PFN3rZPebHUgwKpb1nQWcIC&index=1
Dismantling: https://www.youtube.com/watch?v=-QSWB4H6QM8
DPS3012 power test + chs: https://www.youtube.com/watch?v=q1wy0gzXgGo
DPS 5005 tear down video: https://www.youtube.com/watch?v=BklUuj5-j10
General Information
IN+: Input positive IN-: Input negative:
OUT+: Output positive: OUT-: Output negative
Note: Input voltage range is DC 6-60V and 60v is the limit voltage; please leave a room to use. Or else it will be burnt. The input must be DC power supply, not AC 220V, or else it will be burnt too. Though this module has re connection protection and output short circuit protection, you can muse be in strict accordance with connection descrtion to connect. If you connect the supply power with output, the module will be burnt.
Panel descrtion
1-Voltage setting/Page up to choose/Shortcut extract M1 data group
2-Data setting/ Extract value of the specified data group/Store value into the specified data group
3-Current setting/Page Down to choose/Shortcut extract M2 data group
4-1.44 inch color LCD screen
5-Coding potentiometer/Data adjustment/Lo all button
6-Open or close output
Display interface descrtion
7-The preset value of output voltage
8- The actual value of output voltage
9-The actual value of output current
10-The actual value of output power
11-The actual value of input voltage
12-The preset value of output current
13-Key lo or unlo prompt
14-Output normal or not prompt
15-Constant voltage and constant current status prompt
16-Data set prompt
17-Open or close output prompt
18-Preset output voltage
19-Preset output current
20-Preset over- voltage
21-Preset over-current
22-Preset over-power
23-Preset screen brightne
24-Preset data set
25-The actual value of output voltage and output current
Operating instructions
When connect the power supply, the screen shows welcome window firstly and then comes into main interface. On the main interface, the output set voltage value and the output set current value is on the top of the screen. The big font value on the left are the current real output voltage, the current real output current and the current real output power. Input voltage is on the bottom of the screen. There are some running status icons on the right of the screen, key lo icon, abnormal output status icon, constant voltage and constant current icon, data set t icon and opening or closing output icon.
Set the output voltage and output current on the main interface.
Pre V/↑key shortly, you can enter into voltage setting status. Then pre the coding potentiometer, and then enter to adjust the numerical value. Pre coding potentiometer to enter into the status of adjusting the numerical value you want to adjust. Turn coding potentiometer to adjust the numerical value. Turn by clowise rotation to increase the numerical value; Turn by counterclowise to decrease the numerical value. If you want to exit adjusting the numerical value, pre shortly V/↑. In the same time the preset value will be stored. Or you can do nothing in one minute, the status will be automatically existed and the preset will be stored too. You can pre A/↓to set the output current by the same way.
Set the data on the data setting interface
On the main interface, you can pre SET key shortly to enter into data setting interface. On the data setting interface, pre shortly V/↑or A/↓ to page up or page down to U-SET or I-SET, and then set the output voltage and output current by same way used in the main interface .
Set the protection value.
Page up or page down to S-OVP, S-OCP or S-OPP place to set over-voltage value , over-current value and over-power value correspondingly; when the value is up to the setting value, output will be closed. And then pre shortly the coding potentiometer to enter into the status of adjusting the numerical value you want to adjust. Turn coding potentiometer to adjust the numerical value. If you want to exit adjusting the numerical value, pre shortly SET key.
Adjust the brightne of screen.
Page up or page down to B-LED, and then pre shortly the coding potentiometer to enter into the status of adjusting the brightne of screen. Turn coding potentiometer to adjust the numerical value you need. If you want to exit adjusting the numerical value, pre shortly SET key. There are six brightne levels of LCD screen, 0-5 level. Rank 0 is the darkest; rank 5 is the brightest. You can choose what you like.
Data setting and store the specified data group.
Page up or page down to M-PRE, and then pre shortly the coding potentiometer to enter into the status of choosing the data groups. Turn coding potentiometer to choose the data group you need to view. Then the data group you need will be displayed. And then pre the coding potentiometer to enter into status of changing output state. Turn coding potentiometer to choose ON or OFF. When choose ON, the data group is extracted and the output status remain the same. When choose OFF, the data group is extracted and the output is closed. If you want to exit choosing data set, pre shortly SET key. Then pre shortly V/↑or A/↓ to page up or page down to other place to adjust the data you need. After data setting done, keep preing SET key more than 2s, all the data you set are automatically stored into the specified data group. In the same time, you can see the group number on the right of screen. At last you can pre shortly SET key ba to the main interface.
Set default boot open or close output
Page up or page down to S-INI, and then pre shortly the coding potentiometer to enter into the setting status. Set ON, default boot open; set off, default boot close.
Function descrtion.
Open or close the output .
You can pre ON/OFF key to open or close the output on any interface.
Lo the button to avoid wrong operation.
On the any interface, you can keep preing coding potentiometer more than 2s, all buttons are loed. You can see the key lo icon on the right of screen. If you want to unlo all buttons, keep preing coding potentiometer more than 2s, all buttons are . The key unlo icon will be displayed on the right of screen.
M0-M9 ten groups data group
M0 group is the boot default data group. When you extract the data group you need, this data group will cover M0 data group and be automatically stored on M0 data group.
Extract Shortcut storage data group M1 or M2.
On the main interface, keep preing V/↑or A/↓ more than 2s, you can extract Shortcut storage data group M1 or M2 quily. In the same time the corresponding data group number will displayed on the right of the screen.
Extract the specified data group.
On the main interface, keep preing SET key more than 2s, the sequence number of data group will be displayed on the right of the screen, you can turn coding potentiometer to choose data group you need. And then pre shortly SET key, you can extract the specified data group you need.