This website uses cookies
This website uses cookies. For further information on how we use cookies you can read our Privacy and Cookie notice
This website uses cookies. For further information on how we use cookies you can read our Privacy and Cookie notice
Shipped from abroad
Free return within 7 days for eligible items.Details
CharacterL
100%Seller Score
26 Followers
Shipping speed: Excellent
Quality Score: Excellent
This product supports serial ports and computer . If you need to connect to a computer, please leave your email addre when placing an order, and we will send you the serial port driver and computer via email.
In order to maintain the advanced nature of the product, product features will be slightly adjusted and updated, which will not affect the use of the features, without prior notice. If you mind, please do not purchase, thank you.
Product FeaturesThe battery internal resistance can measure the internal resistance and voltage of the battery at the same time. It adopts a Kein four-wire test cl, which can better avoid the influence of contact resistance and wire resistance, and can perform more accurate measurements.
This product adopts intelligent control, LCD display, and implanted Kalman filter mathematical algorithm. It has the advantages of high precision, high efficiency, low cost, light weight, energy saving and environmental protection. Built-in 1000mAh lithium battery, 5V charging, Android mobile phone charger can be used, very convenient.
This product is widely used in various battery production, maintenance, testing, scientific research laboratories and other occasions. It can also be used to measure the AC resistance of s and low-resistance high-precision resistance.
RC3563 battery internal resistance True four-wire AC internal resistance sorter Lead- lithium battery UPS test.
Optional Acceories Actually shped according to the acceories included in the selected ture.
High-end probe is gold-plated, stable sturdy and durable.
High-end probe parameters
Electronic Specifications
Max Continuous Current Contact Sleeve:6A
Max Continuous Current Contact Plunger:3A
Hole Size
Recommended Min Center : 7.0mm [0.2756]
Mounting Hole Size : 4.0mm [0.1575]
Applications
Battery System Activated Element Test
Battery Contact Test
Capability of Electric Current Signal Transmiion Test
Mechanical Data
Full Stroke : 4.0mm [0.1575]
Outter Stroke : 3.0mm [0.118]
Central Stroke : 20mm [0.0787]
Outter Spring Force : 500g±20%
Central Spring Force : 130g±20%
The measurement result is displayed immediately, and the response is fast and sensitive, without waiting.
The size of the instrument is moderate, suitable for handheld work.
The test wire is regular, the craftsmansh is good, and the design is reasonable.
Technical Index
Note: During the test, try to make the test leads or clamps parallel to reduce the influence of eddy current.
calibrated before shment, and try not to make any other settings.
Test parameters
AC resistance, DC voltage
Measurement accuracy
Resistance:0.5%
Voltage:0.5%
Measuring range
Resistance:0.001mΩ ~ 200Ω
Voltage:0.001V ~ ±100VDC
Signal source
Frequency: AC 1kHz
Current: 20mΩ range 50mA; 200mΩ/2Ω range 5mA; 20Ω/200Ω range 0.5mA
Range
6 ranges automatic and manual
3 ranges automatic and manual
Test speed
5 times/sec
Correction
Resistance: each range is individually and manually calibrated without affecting each other
Voltage: each range is individually calibrated manually, and does not affect each other
Factory settings
Save the factory information, one key can restore the factory state
Energy saving settings
about 10 minutes delay, automatic shutdown without any operation
Applicable
Cell phone, computer, electric vehicle and other battery maintenance, battery factory and testing
Show results
LCD display, direct reading
Power supply
Built-in lithium battery, using 5V/1A charging
Size
Length, width and height=166*80*28
Language
Chinese or English can be switched at will
Key Descrtion
1. Short pre "enter key " to turn on.
2. Long pre "enter key " to shut down.
3. Pre the "set key" to enter the setting state, then pre the "select key" to select different functions, and then pre the "enter key" to enter the corresponding function.
4. Enter the resistance calibration/voltage calibration state. At this time, the test line should clamp the calibration resistance or voltage, pre the "set key" to select the gear to be calibrated, and then pre "+" and "-" to adjust the displayed value to be equal to the calibration resistance or voltage , Pre the "select key" to select "ok" or "Cancel", and finally pre the "enter key " to decide whether to save or cancel.
As can be seen from the table below, the larger the battery capacity, the smaller the internal resistance. It is generally believed that if the internal resistance of the battery is greater than 1.25 times of the factory standard, it indicates that the battery has been severely aged and needs to be replaced in time.
Actual Use Case
Sampling resistance
PC Interface
Frequently Asked Questions
1. Zero adjustment problem, the cl short circuit is not zero?
Answer: The short circuit of the two cls is not zero and there is x.xxxmΩ, which is a normal phenomenon. Only when the two cls are in perfect contact will the minimum value (it may be 0 or very close to 0). It does not matter if it is not 0. During the measurement proce, the internal program has calculated the theoretical zero point, which does not affect the accuracy and does not need to be calibrated to zero.
2.Does the battery need to be fully charged for measurement?
Answer: The battery's full and depleted state will not affect the battery's internal resistance, and can be measured, with minimal changes in internal resistance (except for defective batteries).
3.The measurement result is jittery, inaccurate, unstable?
Answer: The test result is unstable. It may be that the test cl is in poor contact with the battery, or the battery under test is unstable, the electrode has an oxide layer, or there is a strong ic field around it.
4.The measured internal resistance is greater than the battery internal resistance?
Answer: When measuring large-capacity batteries (the internal resistance is very small), you must pay attention to the position of the cl during the measurement. The internal resistance of the battery electrode or connecting wire is often greater than the internal resistance of the battery itself. Pay attention to the position of the cl and make good contact.
5. Is it poible to measure xxxx batteries?
Answer: The instrument can measure any type of batteries, including lithium batteries, lead- batteries, nickel-chromium batteries, dry batteries and so on.
6.Why can the internal resistance be measured to judge whether the battery is good or bad?
Answer: The same battery will gradually wear out during use, the capacity becomes smaller and smaller, and the internal resistance becomes larger and larger. The smaller the internal resistance of the same battery, the stronger the load capacity, otherwise it will heat up or fail to move. The better the performance of the battery, the slower the , the worse the quality of the battery, the faster the .
7. What is the general internal resistance of an 18650 lithium battery?
Answer: The internal resistance of the new 18650 lithium battery is generally below 50 milliohms, the better is about 20 milliohms, the general is about 30 milliohms, and the worse is above 50 milliohms.
8.How much battery capacity can be measured?
Answer: You can measure batteries of any capacity, no matter how big it is, as long as the internal resistance is within 0-200 milliohms and the voltage is within 100V.
9. Can the internal resistance be measured online, and can the UPS power supply be tested?
Answer: It can be tested online without affecting the working of the battery, so the battery can be tested continuously during UPS maintenance.
About shpingThis product has no ratings yet.
Subscribe to our newsletter
and be the first one to know about our amazing deals!