Features:
1.Use high-quality materials with guaranteed quality
2.The upgraded CNC charging control module is suitable for 6-60V batteries
3.The product can automatically power off, saving power and effort, effectively extending battery life
4.Exquisite appearance and beautiful arrangement of components
5.Wide application range, suitable for various industrial occasions
Parameters:
Control voltage: DC6-60V
Control current: ≤ 30A
Control accuracy: 0.1V
Output type: DC output
Voltage error: ± 0.1V
Applicable range: Various types of lithium-ion batteries
Usage:
Set startup voltage:
When the voltage is displayed normally, click the start voltage button to display the start charging voltage. Press and hold the start button, the Nixie tube flashes, enter the setting mode, and set the start charging voltage value through the start and stop buttons
Set stop voltage:
Under the normal voltage display status, click the stop voltage button to display the stop charging voltage. Long press the stop button, the Nixie tube flashes, enter the setting mode, and set the stop charging voltage value through the start and stop buttons
Factory reset:
Press and hold the start/stop button at the same time, turn on the power, and the digital display 888 is displayed, that is, Factory reset
After the charging voltage reaches the stop voltage, there will be a delay of two minutes to turn off the charging
Method for determining the charging voltage range:
According to the calculation of the voltage on the battery, slow charging is usually used for battery charging. First, the initial charging voltage is about 1.2 times of the rated voltage, and the speed regulating charging current is about 1/10 of the current of the battery's Nameplate capacity. For example, the charging voltage of a 6V50AH battery is about 7.2V, and the speed regulation charging current is 5A
Reference formula:
Charging voltage=rated voltage * 0.9
Charging current=rated current * 0.1
Stop voltage=rated voltage * 1.2