The transformer is AC 220V to AC 9V
Operation descrtion
3.1 Operation display panel indicating lamp
3.2 Show state descrtion
Common control of the controller 3 Operation state, welding preparation, parameter query, parameter change
Welding preparation : Running light Always Time, current, interval, time, current indicating light out
Parameter query The operation indicates the lights, time, current, interval, time, and current relative to the light, the digital tube is always bright, and the value of the display is the corresponding parameter value.
Parameter change Operation indicator lights out, time, current, interval, time, current corresponding indicator light, digital tube flicker, and display value is corresponding parameter value change value.
3.3: welding preparation
By [selection] / Adjust the encoder counter clockwise rotation, Make the running light bright, time, The current, interval, time, and current indicate the extinction of the lamp, and the welding can be carried out at this time. The value of the digital tube is the current welds value.
3.4: voltage calibration
Because this controller has the function of net preure compensation, it is neceary to calibrate the voltage when the first time is installed, only one can be calibrated. (as long as the power transformer is not replaced, no recalibration is needed.)
Calibration operation:
In running state, the lights that are kept on a micro motion until the time, the current and the interval are all lit up. At this time, the market voltage is measured by , for example, the voltage measured at that time is 225V So, the rotary encoder makes the value of the digital tube display 225 You can then double click the fretting switch and exit the calibration.
3.4: parameter changes
When querying parameters, by [selection] / Adjust the encoder to rotate, query, indicating the light, the digital tube shows the parameter values of the current corresponding parameters.
For example: rotation [choice] / In order to make the interval light bright, the value of the digital tube is the interval time.
3.4: parameter changes
Take the change interval as an example
3.5 : count zero
This controller has the function of welding counting. In the proce of welding, each welding, the welding count is added automatically. 1 . Counting range 0-999.
If you want to clean up, when running, double click into / Preservation] on, count automatic clear 0.
4: Baby detail ture