CharacterL
100%Seller Score
26 Followers
Shipping speed: Excellent
Quality Score: Excellent
* If you need low cost no battery inside type, pls click : 2/3/4-wire 0-20mA 0-10V Signal BRT LB01GNB
New Features: • Max. Output range: max. -10V to 10V., 2/3/4-wire 0-22mA sink or source signal. Voltage output can be exactly 0.00V •O utput range can be 0-20mA, 4-20mA, 0-22mA, 0-1V, 0-5V, 0-10V, 0-2.5V, 0-3.3V, -5V to 5V, 1-5V, 2-10V, etc. switchable and adjustable. • Display modes can be: actual current/voltage signal value display, 0.0-100.0(%), 0.0-50.0 (Hz), switchable. • User can set 9 x fast signal output points, more convenient to do debugging. • Have battery capacity status indicator, and battery voltage value display function. • Support 24V operating power supply via wiring terminals and 5V from USB port, can be used in indoors or outside industrial site. • 1000mAH 3.7V re-chargeable battery embedded inside, *Automatic stopping recharging battery when battery has been fully charged.. • Output accuracy can be calibrated by user, precision 0.01V, 0.01mA output and LED display output signal value accurately. • Adjusting steps can be fine adjustment or rough adjustment, switchable. • Have short-circuited protection circuits and polarity re connection protection circuits in Brightwin signal . • Refined user-friendly external shell, refined accurate encoders' knob to adjust output signal, more slim size. *Its default output range is 0-10V, 0-20mA, user can adjust it to make it output -10V to -10V, 4-20mA, etc., output ranges. *Output accuracy can be calibrated by user.Technical Parameters
Referential Application Circuits
* Sampling resistance is only for reference, no needed to add when using our .
Parameters Programming Examples:
>> Modify "F001" Coarse/Fine adjustment mode:
>> "F006" Precision calibration steps explanation: * When doing F006 precision calibration, please do adjust the signal output to 10V or 20mA firstly. Figure 1→2:Pre down and hold Knob for 2 seconds till it displays parameter code: "F001"; Figure 2→3: “+” Clockwise rotation once, Display“- - - -”; Figure 3→4: Input Paword “+ – – +”, Display“- - - -”; Figure 4→5: Pre “OK”, If paword is correct, displays “F002”, Otherwise displays “Err” and Exit; Figure 5→6: Rotate Knob till displays “F006”; Figure 6→7: Pre down the knob “OK” to set the value of “F006”, and then modify the value so that the actual output signal value (measured by high precision ) equals to the value displayed in LED panel (10V/20mA); A high precision needed in that step. Figure 7→ : Pre down knob “OK” to Save. Otherwise parameters will not be save if there are no actions taken for more than 10 seconds. * Its output range and display mode setting methods are the same to that steps above, please contact us to get user manual or technical support. * Battery recharging time required is 3-4 hours. When recharging the battery, the LED screen is on (cannot be off), and it can automatically stop to recharge the battery once it has been fully charged. It provides convenience for user to use or 5V, 1A out AC/DC power adapter to recharge it and use it to do calibration at the same time. Please refer to the User Manual to get more details.
Parameters Code Number Table
Parameters Programming Insructions
1.Pre down and hold on for 2 seconds to enter into parameter setting states, then LED meter displays "F001" (F001 is Parameter Code Number); 2.Turn the Knob to change the parameter code number (When entering into “F002”, user needs to enter paword "+ - - +" first. ); 3.When displaying parameters code number, Pre down knob "OK" to enter into the corresponding parameter value setting state, then rotate knob to modify the parameters. 4.Pre down the knob "OK" to save parameters setting and exit. LED meter displays next parameters code number ( If haven't enter the paword, the signal will be returned back to normally adjusting mode after setting "F001" value ); 5.Rotate the knob directly till the last parameter code number "Fend" is displayed, then pre down the knob to confirm and save. The parameters setting is completed, and the signal returns back to normally operating status. 6.In parameters setting proce, if no any operation to the for more than 10 seconds, the signal will exit setting status and return back to normally operating status. Portable 0-5V 0-10V 4-20mASignal Package including: 1 Unit x Siganl New Upgraded Version 1 Pcs x High quality 2A USB Cable 1 Set x Profeional User Manual (Easy to understand). *** If you like low cost the same signal without battery inside type, please choose BRT LB01G (click): Portable 0-5V 0-10V 4-20mA with LED Display Adjustable Out DC Current Voltage Signal High PrecisionAbout shping