Function:
1.The external temperature detector can detect the temperature.
2.Set the start and stop temperature.
3.Cycle timing, start and stop time, timer switch.
4.It is widely used in intelligent control, such as carbon heating, aquaculture,greenhouse, home life and other places.
5.Screen lock protection function.
6.Pre the RESET to restore the screen for one second, and restore the factory settings.
7.Memory function after power off.
Technical parameters:
Voltage 110V~230V AC 50Hz/60Hz
EU FR Plug:16(2)A 230V-Max .3680W.u
UK Plug:13(2)A 230V-Max .2900W.u
AU Plug:10(2)A 240V-Max .2400W.u
US Plug:15(2)A 120V-Max .1800W.u
Temperature range: -40~120°C
Accuracy: +/- 1%
Timing Accuracy: MAX 10 minutes
Open circuit (or le than -40°C), the first row of the screen flashes display ''E1'', -40~-45°C, display -40°C
Short circuit( or more than 120°C ), the first row of the screen flashes displaty ''E2'', 121-129°C display 120°C
Lower than -10°C, or higher than 100°C, it will not display value behind the decimal point
Refrigeration mode, start temperature > Stop temperature
Heating mode, start temperature < stop temperature
Mode on:
Pre MODE. LCD display: temperature control mode
Timing mode F01-F04
F01 Cycling timing mode, start time(ON)/stop time(OFF) cycling timing.
F02 Count down ON mode, now Ti.s OFF, delayed(start time) ON
F03 Count down OFF mode, now Ti.s ON, delayed(stop time) OFF, countdown completion, turn off the output and exit the run
F04 Count down ON Count down OFF mode, now Ti.s OFF, delayed(start time) ON, After starting delayed ( Stop time )OFF, Stop the time to finish the countdown, close out the output and exit the operation
Temperature correction function:
Long pre mode on on electricity, real time temperature calibration after 2 seconds
Real time temperature correction range: -9.9~9.9°C
Long pre the SET for 5 seconds to automatically exit, do not save modification
Long pre MODE on to exit, save the cuttent correction modification