Product parameters
Product model: ZFX-W2062C
Product Name: Intelligent high precision digital humidity controller
Control humidity range: 1%RH-99%RH
Load power: 10A/DC12V/24V
Humidity measurement range: 1% RH-999% RH measurement error:
±3% RH (good environment temperature is 25℃)
Control humidity accuracy: 1% RH display: 1% RH
Humidity return: adjustable between 1-50% RH
Supply voltage: DC12V/24v
Output type: 10A relay output
Probe type: humidity resistance r
Size: 48*29*22mm (long * section * high)
Installation hole: 46*27m
Moisture control object: dehumidification or humidification
Probe line length: 1.5m line length
Working environment: humidity 90% RH no frosting
Parameter code and settings
Code
Descrtion
range
Factory settings
P0
Humidification/dehumidification
H/C
C
P1
Ba
1-50%RH
P2
Set the maximum limit
99
95
P3
Set the minimum limit
1
5
P4
Temperature correction
-10
10
P5
Delayed start
0-10
1
P6
Restore Factory settings
ON- OFF
OFF
Setting instructions
Connect the power supply and load to power the controller. The red color above shows the humidity, blue below.
Also red) is displayed as the desired humidity, and pre STG (+) ENT (-) to set the required humidity
After the setting is completed, wait for 3 seconds to automatically confirm the return. At this time, the controller automatically performs relay energization according to the setting.
For 10A relays, to meet high power loads, please make sure the line is correct.
Indicator light, digital tube status descrtion
Indicator light: off means the relay is off, steady light means the relay is closed
Digital tube: The above shows that LL is the r open circuit, indicating that HH is out of the measurement range, the humidity will forcibly open the relay.
Display - for ultra high humidity protection.
Parameter function descrtion
Pre and hold SET for 5 seconds to enter the main menu settings, pre SET (+) ENT (-) to switch P0-P8, when adjusting parameters P0-P8 parameters
If you need to adjust P0, pre SET on (+) ENT (-) at the same time, adjust 0K, then control SET (+) ENT (-)
Once confirmed, P1-P8 and P0 set the parameters in each code according to their own needs.
Panel settings:
Wiring diagram:
More Products Please Cli Below:
Category List
For Arduino DiY For Raspberry Pi Wirele Module Step UP/Down Module
ESP8266 Series CH340 Series Relay Switch Tools Temperature Controller
USB LED/LCD Modules r Converter & Regulator
DC/AC/ Motor Signal Gengerator Development Expansion Board
About shpingThis product has no ratings yet.
Subscribe to our newsletter
and be the first one to know about our amazing deals!