This website uses cookies
This website uses cookies. For further information on how we use cookies you can read our Privacy and Cookie notice
This website uses cookies. For further information on how we use cookies you can read our Privacy and Cookie notice
Shipped from abroad
Free return within 7 days for eligible items.Details
herhrehb
60%Seller Score
Be the first to follow
Shipping speed: Very Poor
XY-CD60 Dial Charging Timer Controller DC 6 -60V Lithium Lead Acid Battery Charging / Discharging Protector Controller Module
Description:
This Product is a battery charge and discharge controller module. It can be used for DC 6 -60V lithium/lead-acid battery.
Feature:
Multi-function test instrument
Dual mode work
Support charging protection
Support discharge protection
Support set the charging/discharging time
Automatic s
HD LCD display
Multi- display
Support power saving mode
Supports automatic battery
Comfortable outer casing
:
Product name: Lithium Battery Charging/Discharging Controller
Model: XY-CD60
Working voltage: DC 6 -60V
Prevent Over-charge
Prevent Over-discharge
Display battery voltage, percentage and operating time.
Charging Time Control: 00:00 -99:59 hours
Discharging Time Control: 00:00 -99:59 hours
Delay: 0 -999 seconds
Work Temperature: -40 -85℃
Work Humidity: 0% -95%RH
Size: 79*43*27mm
Function:
Module supports 2 working modes: Charging Control P-1 and Discharging Control P-2.
Charging Control P-1:
This mode is used for charging control to prevent overcharging. Display symbol IN indicates charging mode.
Discharging Control P-2:
This mode is used for battery discharge control to prevent battery over-discharge and delay battery life. Display symbol OUT indicates discharging mode.
Battery voltage percentage:
It is value get from battery voltage V, Lower Limit Voltage Value DOWN and Upper Limit Voltage Value UP.
Calation formula: V/UP-DOWN.
Automatic check: Screen will display and fing ERR if the Lower Limit Voltage Value DOWN is more than the Upper Limit Voltage Value UP.
[Charging Control P-1 Mode]
Input terminal connect DC 6V-60V charger which use for battery.
Output terminal connect 1pc of DC 6 -60V battery. It will display 0.00V and nbE if the battery does not meet the requirements.
Output turn ON and the input charger starts charging the battery if battery voltage is less than the Lower Limit Voltage Value DOWN.
Output turn OFF and the input charger stops charging the battery if battery voltage is more than the Upper Limit Voltage Value UP.
The symbol IN will fing when charging.
Support set :
Upper Limit Voltage Value UP: Maximum voltage of the battery. Stop charging the battery if it exceeds this value. It is also the overcharge protection voltage value.
Lower Limit Voltage Value DOWN: Battery allowed minimum voltage. Start charging the battery when the battery voltage is lower than this value.
Charging Time OP:
Set battery charging time.
Turn ON charging time control function when the OP value is more than 00:00. Minimum set time value 1minute.
Turn OFF OP control if set 00:00.
Start the timer when turn on output to start charging.
Module turn OFF output to complete a charging process when timing is completed.
Module automatically turns OFF charging time control function if battery voltage is less than the Lower Limit Voltage Value down and fing H:ER that means the unreasonable time setting. It means insufficient charging and needs to continue charging the battery. Press any key to stop fing.
Record and display charging time if disabled Charging Time OP when short press on SET. Clear time if at next charging or exit charging time display interface.
Turn ON Delay Time DOP: Set the delay interval between the first and the second charging. The time range is 0 -999second.
[Discharging Control P-2 Mode]
Input terminal connect 1pc of DC 6 -60V battery.
Output terminal connect suitable load. Note the output voltage is same to battery.
Output turn ON and the battery starts to discharging if battery voltage is more than the Upper Limit Voltage Value UP.
Output turn OFF and the battery stops to discharging if battery voltage is less than the Lower Limit Voltage Value down.
The symbol OUT will fing when discharging.
Support set :
Upper Limit Voltage Value UP: Threshold value to allow battery discharge.
Lower Limit Voltage Value down: Battery allowed minimum voltage.
Stop discharging when the battery voltage is lower than this value.
It is also the over-discharge protection voltage value.
Discharging Time OP:
Set battery discharging time.
Turn ON discharging time control function when the OP value is more than 00:00. Minimum set time value 1minute.
Turn OFF OP control if set 00:00.
Start the timer when turn on output to start discharging.
Module turn off output to complete a discharging process when timing is completed.
Module automatically turns OFF discharging time control function if battery voltage is more than the Upper Limit Voltage Value UP and fing H:ER that means the unreasonable time setting. Press any key to stop fing.
Record and display discharging time if disabled Discharging Time OP when short press on SET. Clear time if at next discharging or exit discharging time display interface.
Turn ON Delay Time DOP: Set the delay interval between the first and the second discharging.
The time range is 0 -999second.
Discharge Turn ON Forced Start Time FOP:
This function is used to prevent the device from starting instantly and reduce the battery voltage, so that it is lower than the Lower Limit Voltage Value down and causing the module to automatically turn off the output and causing the battery can't discharge properly.
The module will chethe battery voltage again if enabled Discharge Turn ON Forced Start Time function.
on Description:
press means need keep press for more than 5second.
[UP on]
Short press to switch display charging/discharging time and battery voltage percentage.
press to switch work mode. IN is Charging mode and OUT is Discharging mode.
Short/press to increase value at set mode.
[DOWN on]
Short press to turn ON/OFF output.
press to turn ON/OFF display status L-P power saving mode: ON: Turn ON power saving mode. The display screen will turn OFF after 5~10minutes. Press any on to resume display.
OFF: Turn OFF power saving mode. The display screen will keep ON all the time.
Short/press to decrease value at set mode.
[SET on]
Short press to automatically switch/query display s UP/DOWN/OP/DOP at charging mode and UP/DOWN/OP/DOP/FOP at discharging mode in normal display interface. Short press to switch select set in set mode.
press to enter into set mode.
Keep press about 5second to save values.
Use steps:
Connect right input voltage at VIN+ and VIN-.
press on SET to select work mode.
Short press on SET to switch s.
Short/press UP/DOWN to increase/decrease value.
Keep press about 5second to save values.
Remove input and connect load.
Connect right input voltage at VIN+ and VIN- again.
Application:
Load
Circuit
Battery discharge
Factory equipment
Ordinary load
Power supply
Auxiliary measurement charger
Output current capability
Charger
Note:
Load terminal can't short circuit.
It is a charging/discharging controller but not a charger!
It can't be used as a charger!
Please read use manual and description before use.
FAQ:
Q: What is the control voltage range? What is the applicable battery range?
A: Control voltage range is DC 6V-60V. But battery voltage max is 48V. Because the voltage of 48V battery is 60V after fully charged.
Q: Why relay is automatically turned on and off continuously after power on and fing light?
A: This is because your charging current is too large or the battery capacity is too small that cause the battery voltage to immediately exceed the Lower limit voltage 'DOWN' value and then relay will OFF. But the voltage drops quickly to the Lower limit voltage 'DOWN' after Relay OFF and then start to charging. Cycle and cycle. At this point you have to reduce the charging current. Usually the charging current is 10-15% of the battery capacity. For example, if the battery capacity is 20AH, the charging current is 2-3A. Note that high current charging can cause the battery to heat up, , bulging or even exploding.
Q: What control method?
A: This is the voltage control. For example: Lower limit voltage 'DOWN' is set to 12.0V. Upper limit voltage 'UP' is set to 14.5V. It will close output when the voltage is charged to 14.5V. Relay will ON and begins to charge when the voltage is reduced to 12.0V.
Q: Can it be automatically cycled?
A: Yes, it can. Voltage control mode only controls turn-off and turn-on.
Q: Can it limit the current?
A: It can't limit current, the charging current is completely dependent on your charger.
Q: Can I charge a 24V battery by inputting 12V? Or charge a 12V battery by inputting 48V?
A: This is a simple voltage controller just for ON/OFF. It can' t change output voltage. So what kind of charger should you prepare for charging the battery!
Package Included:
1 * Lithium Battery Charging/Discharging Controller
This product has no ratings yet.
Subscribe to our newsletter